from the threaded mandrel / threaded sleeve again
in emergency mode.
2 .10 DESCRIPTION OF MASKS
2 .10 .1 Starting mask / working mask in
unlocked state
The starting mask is displayed in unlocked state
after insertion of the battery and during the setting
of fasteners.
Figure h
OK
OK
Battery: 80%
Force: 10A
Spindle: T
Standby: 200S
Warnings: On
File: 00
Counter: Off
Service: 300.000
Starting mask / working mask
Designation Description
Battery
Displays the charge status of the
inserted battery.
Force /
Stroke
Displays the set force if
force-controlled setting mode is
selected.
Displays the set stroke if
stroke-controlled setting mode is
selected.
Spindle
Displays
T
if “Trigger” spin on
mode has been selected.
Displays
M
if “Threaded
mandrel / threaded sleeve” spin
on mode has been selected.
Standby
Displays the set standby time in
seconds.
See chapter 3.5
Warnings
Displays whether the acoustic
warnings are on or off.
See chapter 3.5
File
Displays the number of the
loaded configuration when a
configuration has been loaded.
Displays
None
when no
configuration has been loaded.
See chapter 3.5
Designation Description
Counter
Displays the number of set
fasteners when the counter is
switched on.
Displays
Off
when the counter is
switched off.
See chapter 3.5
Service
Displays how many fasteners
can still be set before the
setting tool should be sent in to
HONSEL Service.
2 .10 .2 Starting mask in locked state
The starting mask is displayed in locked state after
insertion of the battery.
Figure i
OK
OK
Rivdom eVNG Lock
Battery: 87%
Force: 10
Counter: Off
Service: 300.000
Starting mask locked
Designation Description
Battery
Displays the charge status of the
inserted battery.
Force /
Stroke
Displays the set force if
force-controlled setting mode is
selected.
Displays the set stroke if
stroke-controlled setting mode is
selected.
Counter
Displays the number of set
fasteners when the counter is
switched on.
Displays
Off
when the counter is
switched off.
See chapter 3.5
Service
Displays how many fasteners
can still be set before the
setting tool should be sent in to
HONSEL Service.