Sample Test Report
Figure 117A (Sheet 9)
010 SSB 14.4900 MHz PASS
VSWR 1.08 B0 C*00C3 D1 E0 L*0250 N*00 R0 E14.491 N002/001
011 SSB 19.5100 MHz PASS
VSWR 1.15 B0 C*00CB D0 E0 L*002A N*0B R0 E19.512 N002/001
012 SSB 22.9900 MHz PASS
VSWR 1.13 B0 C*0184 D0 E0 L*0012 N*04 R0 E22.992 N002/001
013 SSB 23.0100 MHz PASS
VSWR 1.20 B0 C*0166 D0 E0 L*000F N*04 R0 E23.011 N002/001
014 SSB 29.9900 MHz PASS
VSWR 1.23 B0 C*00DF D0 E0 L*0008 N*01 R0 E29.991 N002/001
----------------------------------------------------------------------------
Task23 : System Receive Test
# Test-Name Status
--- ------------------------------ ---------------------------------- ------
001 SSB 2.0330 MHz PASS
002 SSB 4.6996 MHz PASS
003 SSB 7.3992 MHz PASS
004 SSB 10.0328 MHz PASS
005 SSB 12.6994 MHz PASS
006 SSB 15.3660 MHz PASS
007 SSB 18.0326 MHz PASS
008 SSB 20.6992 MHz PASS
009 SSB 23.3658 MHz PASS
010 SSB 29.9660 MHz PASS
----------------------------------------------------------------------------
Task24 : Fault History Initialization
# Test-Name Status
--- ------------------------------ ---------------------------------- ------
001 Enter Cplr Serial Number PASS
Coupler Type is FK516
Serial Number 0016 entered into the Coupler
Part Number 964-0453-011 entered into the Coupler
002 Erase Fault History PASS
----------------------------------------------------------------------------
----------------------------------------------------------------------------