Honeywell
COMPONENT MAINTENANCE MANUAL
PART NUMBER 964-0452
I.B.1516A Page 703/704
Mar 30/01
23-12-01
dures of paragraph B. When units are removed from storage, they should be completely func-
tional tested to determine operational status prior to being placed into service.
A. Temporary Storage
(1) Place equipment in a waterproof plastic bag.
(2) Place a packet of silica gel or other dessicant in bag.
(3) Seal open end of plastic bag.
(4) Store on rack away from vibration and shock.
(5) Storage temperature range shall not exceed –55°C to +71°C (–67°F to +159.8°F).
B. Extended Storage
(1) Place equipment in a waterproof plastic bag.
(2) Place a packet of silica gel or other dessicant in bag.
(3) Seal open end of plastic bag.
(4) Place equipment in corrugated cardboard carton (preferably the original shipping carton)
with packing.
(5) Store in clean, dry area, away from vibration and shock.
(6) Storage temperature range shall not exceed –55°C to +71°C (–67°F to +159.8°F).
(7) Humidity range shall be 10% to 95% noncondensing.