
When enabled, automatically launches (subject to the specified Delay in seconds) the application after the unit is rebooted. If a
Delay in seconds is specified, AppLock waits for the specified period of time to expire before launching the application. The
Delay default value is 10 seconds; valid values are between 0 “no delay” and a maximum of 999 seconds.
Retries
This is the number of times the application launch will be retried if a failure occurs when the application is automatically
launched at bootup. Valid values are between 0 (no tries) and 99 tries or -1 for infinite. Infinite tries ends when the application
successfully launches. The default is 0 retries.
Delay
This timer is the time that AppLock waits prior to the initial launch of the selected application when it is automatically launched
at bootup. Delay default is 10 seconds. Valid values are between 0 seconds (no delay) and 999 seconds.
The Auto At Boot delay is associated for each application; it will be either a value specified by the Administrator or it will be the
delay default value. At startup, when a delay has been assigned for each application, AppLock waits for the delay associated
with the first application to expire before launching the first application then AppLock waits for the delay associated with the
second application to expire before launching the second application. AppLock continues in this manner until all applications
are launched.
Note:
A “Global Delay” can be accomplished by setting a timed delay for the first application to be launched
(by lowest Order number) and no delay (0 seconds) for all other applications.
Note:
Launch order is determined by the Order specified in the Application tab. The Order value does not
have to be sequential.
Auto Re-Launch
Auto Re-Launch
Default is Enabled.
When enabled for a specific application, automatically re-launches it (subject to the specified Auto Re-Launch Delay in
seconds) after it terminates. This option allows the Administrator to disable the re-launch operation. AppLock cannot prevent all
applications from closing. When an application that AppLock cannot prevent from closing terminates, perhaps because of an
error condition, AppLock re-launches the application when this option is enabled.
Note:
If Allow Close is enabled and both Auto Re-launch and Manual (Launch) are disabled, the application
cannot be restarted for the end-user or by the end-user after the application terminates.
Retries
3-42
Содержание VX3Plus
Страница 1: ...VX3Plus Vehicle Mount Computer Microsoft Windows CE 5 Operating System Reference Guide ...
Страница 14: ...xii ...
Страница 18: ...Back 1 RAM Ball 2 Power Connector 3 Strain Relief Clamp 1 4 ...
Страница 20: ...1 6 ...
Страница 21: ...Chapter 2 Hardware System Hardware 2 1 ...
Страница 129: ...3 89 ...
Страница 130: ...3 90 ...
Страница 149: ...Enter user name password and domain to be used when logging into network resources 3 109 ...
Страница 155: ...3 115 ...
Страница 180: ...Hat Encoding 3 140 ...
Страница 181: ...3 141 ...
Страница 190: ...3 150 ...
Страница 220: ...4 30 ...
Страница 263: ...Click on the advanced certificate request link Click on the Create and submit a request to this CA link 5 43 ...
Страница 270: ...5 50 ...
Страница 280: ...7 4 ...
Страница 282: ...Honeywell Scanning Mobility 9680 Old Bailes Road Fort Mill SC 29707 www honeywellaidc com E EQ VX3PLUSRG Rev S 5 12 ...