Event and Alarm Types
336
MAXPRO NVR 5.0 Installation and Configuration Guide
B
illustrates a typical region-of-interest box configuration in a combination field of
view.
Figure B-5 Combination Field of View Example
Event and Alarm Types
This section describes about the various default Event and Alarm types with severity level for
Camera, Recorder and SMART VMD.
Camera Level Events and Alarm types
The following table displays the 17 default camera level Events and Alarm types with
description and severity level.
The EventSeverity level above 50 is an alarm and below 50 is an event.
Setting the Alarm Threshold Value
to set the Alarm Severity
Threshold value.
EventID
EventDescription
EventSeverity
3
Camera User Recording Started
20
4
Camera User Recording Completed
20
5
Camera Disconnected
40
6
Camera Connected
40
7
Camera Continuous Recording Disabled
20
8
Camera Continuous Recording Enabled
20
9
Camera Event Recording Started
30
10
Camera Event Recording Completed
30
11
Camera Disabled
20
12
Camera Enabled
20
13
Camera User Recording Error
30
14
Camera NoMotion Detected
40
15
Camera Motion Detected
40
16
Camera Motion Started
40
17
Camera Motion Stopped
30
18
Camera Motion Stopped in all regions
10
Содержание MAXPRO NVR Hybrid PE
Страница 1: ...Document 800 16419V5 Rev D 6 2018 MAXPRO NVR 5 0 Installation and Configuration Guide ...
Страница 2: ...This page is intentionally left blank ...
Страница 4: ...This page is intentionally left blank ...
Страница 14: ...M A X P R O N V R 5 0 Table of Contents This page is intentionally left blank ...
Страница 359: ......