C O N F I G U R I N G M A X P R O N V R
Configuring the Cameras
146
MAXPRO NVR 5.0 Installation and Configuration Guide
6
Figure 6-22 IO page
3.
The
Input(s)
pane lists the inputs for the configured cameras. Select the appropriate
options in the fields as explained in the following table.
4.
The
Output(s)
pane lists the outputs for the configured cameras. Select the appropriate
options in the fields as explained in the following table. Or you can also access the Output
tab in
Viewer
screen.
Field
Description
Global Event ID
Unique event ID
Name
External input name.
Enable/Disable
Enables or Disables the input.
Camera
Displays the associated camera name.
State (CLOSED/OPEN)
The default option is
CLOSED
.
Defines the normal (non-alarm or non-active) state of
the input. For example a normally closed input would
have its input terminal normally connected to common
or ground. To activate the normally closed input, the
input needs to be opened (connection to ground or
common removed). For example: A magnetic door
switch raises alarm if the contacts are open when the
door opens.
Record (No/Yes)
The default option is
No
. If set to
Yes
recording will
starts when an input is activated.
Note
Recording is based on the time you set under
System
tab >
Event recording settings
. You
can specify the
Pre-event time
and
Record For
time to record the video.
Trigger
(NONE/ControlOutput)
The default option is
NONE
. If a control output is
selected, then the selected output is activated when the
corresponding input activates.
Note
A cameras input can only activate the same
cameras output.
Send Alarm Monitor
(NO/YES)
The default option is
No
. If set to
YES
, video will pop up
in the viewer when an input is activated. Ensure that
"
Display Video on Alarm
" check box is selected in the
MAXPRO NVR
Log on
dialog box.
Field
Description
Output Number
Control output number.
Name
Control output name.
State
(CLOSED/OPEN)
The default option is
OPEN
.
Defines the normal (non-alarm or non-active) state of the output
relay contacts.
Camera
Displays the associated camera name.
Содержание MAXPRO NVR Hybrid PE
Страница 1: ...Document 800 16419V5 Rev D 6 2018 MAXPRO NVR 5 0 Installation and Configuration Guide ...
Страница 2: ...This page is intentionally left blank ...
Страница 4: ...This page is intentionally left blank ...
Страница 14: ...M A X P R O N V R 5 0 Table of Contents This page is intentionally left blank ...
Страница 359: ......