SYSTEM DESCRIPTION AND INSTALLATION MANUAL
HS--600 High Speed Data System
23--20--31
30 May 2002
Use or disclosure of information on this page is subject to the restrictions in the proprietary notice of this document.
Page 4--2
C. Power Checks
(1) Check the pins listed in Table 4-1.
Table 4-1. Power Checks
LRU
Connector Pin
Signal
HS--600 HSU
BP1
115 V ac (High)
BP7
115 V ac (Low)
BP2
28 V dc (High)
BP3
28 V dc (Low)
HSD System HPA (Note)
BP1
115 V ac (High)
BP7
115 V ac (Low)
NOTE:
The HPA is also available as 28V dc. See Honeywell Pub. No. C15--5111--005 for installation details.
D. RF Checks
(1) Check the pins listed in Table 4-2. Figure 4-1 shows the receive (RX) path loss and
Figure 4-2 shows the transmit (TX) path loss. These losses are achieved by a
combination of RF coaxial cable losses and installed RF attenuators (the latter, if
required).
Table 4-2. RF Checks
From LRU
Connector Pin
To LRU
Connector Pin
RX Splitter
RX IN
DLNA
J2 (RX OUT)
RX OUT
MCS--3000 SDU or
MCS--4000 SDU or
MCS--7000 SDU
BP13 (RX IN)
RX OUT
MCS--6000 RFU
TP1C (RX IN)
RX OUT
RF Attenuator
IN
RF Attenuator
OUT
HS--600 HSU
BP12 (RX IN)
Combiner
TX OUT
DLNA
J1 (TX IN)
TX IN
HSD System HPA
MP1C (RX OUT)
TX IN
SATCOM System HPA
MP1C (RX OUT)
HS--600 HSU
BP13 (TX OUT)
RF Attenuator
IN
RF Attenuator
OUT
HSD System HPA
TP1C (RF IN)
Содержание HS-600
Страница 15: ...CONTENTS ...
Страница 22: ...INTRODUCTION ...
Страница 27: ...SYSTEMS DESCRIPTION AND OPERATION ...
Страница 42: ...MECHANICAL INSTALLATION ...
Страница 52: ...ELECTRICAL INSTALLATION ...
Страница 64: ...INSTALLATION CHECK ...
Страница 69: ...ADJUSTMENT TEST ...
Страница 78: ...FAULT ISOLATION ...
Страница 81: ...MAINTENANCE PRACTICES ...
Страница 86: ...APPENDIX A ...
Страница 97: ...APPENDIX B ...