SYSTEM DESCRIPTION AND INSTALLATION MANUAL
HS--600 High Speed Data System
23--20--31
30 May 2002
Use or disclosure of information on this page is subject to the restrictions in the proprietary notice of this document.
Page 5--2
Figure 5-1. SDU to PC Cable
(3) Connect the PC using HyperTerminal, ProComm, or equivalent.
(4) Set the terminal settings to: Direct Connect to Comm 1, 9600 N 81.
(5) Press ENTER to see the SDU main menu.
NOTE:
Refer to paragraph 1.A.(5) in section 1 for the periodic data word setup.
(6) Align the inertial reference system (IRS).
(7) Remove the cable from the SDU to the PC.
(8) Connect a cable from the HSU to the RS--232 maintenance port as given in
Table 5-2.
Table 5-2. HSU to RS--232 Maintenance Port Wire List
From HSU Connector Pin
To RS--232 Maintenance Port 9--Pin Female
D--Type Connector Pin
TP6G
3
TP6F
2
TP6J, TP6H
5
(9) Connect a cable from the RS--232 maintenance port to the PC as shown in
Figure 5-2. The cable connector that attaches to the HSU RS--232 maintenance port
is a 9--pin male sub--D connector. The cable connector that attaches to the PC is a
9--pin female sub--D connector.
Figure 5-2. HSU RS--232 Maintenance Cable