SYSTEM DESCRIPTION AND INSTALLATION MANUAL
HS--600 High Speed Data System
23--20--31
30 May 2002
Use or disclosure of information on this page is subject to the restrictions in the proprietary notice of this document.
Page 1--9
Table 1-12. HS--600 Leading Particulars
Characteristic
Specification
Dimensions (maximum):
•
Length . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
•
Width . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
•
Height . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7.64 in. (194.06 mm)
4.90 in. (124.46 mm)
15.26 in. (387.60 mm)
Weight (maximum) . . . . . . . . . . . . . . . . . . . . . . . 11.84 lb (5.37 kg)
Power requirements (AC) (Note):
•
Nominal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115 V rms, 400 Hz
•
Maximum . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 134 V rms, 480 Hz
•
Minimum . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97 V rms, 320 Hz
Power requirements (DC) Note):
•
Nominal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27.5 V dc
•
Maximum . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32.2 V dc
•
Minimum . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20.5 V dc
Power Consumption . . . . . . . . . . . . . . . . . . . . . . 25 W nominal, 40 W maximum
Cooling Requirements . . . . . . . . . . . . . . . . . . . . Select tray from Table 1-15
Connector P1 (Rear) . . . . . . . . . . . . . . . . . . . . . . Radiall Part No. 620--600--237
Mating Connector (P1) . . . . . . . . . . . . . . . . . . . . Radiall Part No. 620--600--238
•
22 AWG Contacts . . . . . . . . . . . . . . . . . . . . . . Radiall Part No. 620--200
•
20 AWG Contacts . . . . . . . . . . . . . . . . . . . . . . Radiall Part No. 620--310
•
16 AWG Contacts . . . . . . . . . . . . . . . . . . . . . . Radiall Part No. 620--330
•
12 AWG Contacts . . . . . . . . . . . . . . . . . . . . . . Radiall Part No. 620--340
•
Size 5 Coax Contacts . . . . . . . . . . . . . . . . . . . Radiall Part No. 620--021
Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Tray, ARINC 600 4--MCU Size
Circuit Breaker Ratings:
•
115 V ac Circuit Breaker . . . . . . . . . . . . . . . . 2 Amp typical
•
28 V dc Circuit Breaker . . . . . . . . . . . . . . . . . 7.5 Amp typical
User Interface (ISDN S/T) . . . . . . . . . . . . . . . . . ITU--T 1.430 (S/T interface)
DSS1/EuroISDN
Environmental . . . . . . . . . . . . . . . . . . . . . . . . . . . Unit must be installed inside pressurized bulkhead (cabin).
Содержание HS-600
Страница 15: ...CONTENTS ...
Страница 22: ...INTRODUCTION ...
Страница 27: ...SYSTEMS DESCRIPTION AND OPERATION ...
Страница 42: ...MECHANICAL INSTALLATION ...
Страница 52: ...ELECTRICAL INSTALLATION ...
Страница 64: ...INSTALLATION CHECK ...
Страница 69: ...ADJUSTMENT TEST ...
Страница 78: ...FAULT ISOLATION ...
Страница 81: ...MAINTENANCE PRACTICES ...
Страница 86: ...APPENDIX A ...
Страница 97: ...APPENDIX B ...