![Honeywell ADEMCO Vista-12C Скачать руководство пользователя страница 96](http://html.mh-extra.com/html/honeywell/ademco-vista-12c/ademco-vista-12c_installation-and-setup-manual_153257096.webp)
Installation and Setup Guide
6-12
Various System Trouble Displays (cont’d.)
no display
no display
Power Failure
If there is no keypad display at all and the LEDs are unlit, operating
power (AC and battery) for the system has stopped and the system is
inoperative.
If the message “AC LOSS” (Alpha display keypads) or “NO AC”
(Fixed-Word display keypads) is displayed, the keypad is operating on
battery power only.
If the battery standby capacity is used up during a prolonged AC
power outage, the control's power will shut down to minimize deep
discharge of the battery.
Comm. Failure
FC
A communication failure has occurred.
Open Circuit
OC
The keypad is not receiving signals from the control and sees an open
circuit.
Long Rng Trbl
bF
Backup Alternative Communication Media communication failure.
Bell Failure
70
Siren supervision failure.
RCVR Jam
90
RF jam detected.
KEYPAD LOW BAT
00 BAT
Wireless keypad low battery
Phone Okay
Cd
The dialer test has been successful (CID code 601).
Dialer Off
dO
The dialer is disabled.
Test in Progress
dd
Walk test mode is active(CID code 607).
Upload Completed
dC
The upload or download session was completed.
Upload Failed
dF
The upload or download session failed before completion.
Содержание ADEMCO Vista-12C
Страница 2: ...Installation and Setup Guide ii ...
Страница 8: ...Installation and Setup Guide 1 4 ...
Страница 100: ...Installation and Setup Guide 7 4 ...
Страница 106: ...Installation and Setup Guide 8 6 ...