Installation and Setup Guide
2-6
Backup Battery
1. Place the 12-volt backup battery in the cabinet.
2. After all connections to the control are completed
and AC mains power has been applied, connect the
red and black flying leads on the control board to the
battery. Do not attach these leads to the battery
terminals until all connections are completed.
Battery Saver Feature:
The battery will disconnect
from the system after its voltage decreases below
9VDC. This assists the control panel in recharging the
battery when AC is restored.
Notes
IMPORTANT:
The panel will not power
up initially on battery power only. You
must plug the transformer in first, and
then connect the battery.
Earth Ground
Metal Cold Water Pipe or Earth Ground Rod:
Use a non-corrosive metal strap (copper is
recommended) firmly secured to the pipe/rod to which
the ground lead is electrically connected and secured.
Notes
•
This product has been designed and tested to ensure
its resistance to damage from generally expected levels
of lightning and electrical discharge, and does not
normally require an earth ground.
•
If an earth ground is desired for
additional protection in areas of severe
electrical activity, terminal 25 on the
control board, or the cabinet, may be
used as the ground connection point.
The examples of good earth grounds
listed at the left are available at some
installations.
AUXILIARY DEVICE CURRENT DRAIN WORKSHEET
DEVICE
CURRENT
# UNITS
TOTAL CURRENT
6128RF Keypad/Transceiver
90mA standby/120mA alarm
6150RF Keypad/Transceiver
80mA standby/105mA alarm
6148 Fixed-Word Keypad
30mA standby/55mA alarm
6164 Keypad w/4-Zone Expander
and Relay
115mA standby/190mA alarm
6150 Fixed-Word Keypad
40mA standby/90mA alarm
6160 Alpha Keypad
40mA standby/150mA alarm
6150V Fixed-Word Display Voice
Keypad
60mA standby/160mA alarm
6160V Alpha Display Voice Keypad
60mA standby/190mA alarm
5881RF Receiver
35mA
5883 RF Transceiver
80mA
5882EU Transceivers
60mA nominal, 85mA peak
4219 Zone Expander
35mA
4204 Relay Unit
15/180mA‡
4229 Zone Expander/Relay Unit
35/100mA‡
TeleCommand
55mA (standby)
119mA (local phone)
85mA (remote phone)
*
TOTAL =
(Current available from Aux. terminals = 600 mA max.)
*
If using wired devices such as PIRs or Dual Tecs, refer to the specifications for that particular unit's current drain.
‡ Figures are for relays OFF/relays ON.