![Honeywell ADEMCO Vista-12C Скачать руководство пользователя страница 26](http://html.mh-extra.com/html/honeywell/ademco-vista-12c/ademco-vista-12c_installation-and-setup-manual_153257026.webp)
Installation and Setup Guide
2-18
Phone Line Connections
Connect incoming phone line and handset wiring
to the main terminal block (via an RJ31X jack) as
shown in the Summary of Connections diagram at
the back of this manual. Wire colors represent the
colors of the cable to the RJ31X jack.
Notes
•
If you are using an Audio Alarm Verification
(AAV) unit, refer to
Audio Alarm
Verification
(AAV)
section for special
wiring connections.
CAUTION:
To reduce the risk of fire, use only
0.6mm O.D. or larger telecommunication line
cord for phone line connections.
Alternative Communications Media
(ACM) Connections
Connect the data in/data out terminals and
voltage input terminals of the ACM to the
control's keypad connection points.
Set the ACM’s address to “03” following the
instructions provided with the ACM.
Notes
•
Use compatible ACMs (e.g., 7845i,
7845C/7835C [in Canada only], AI4164RS,
AI4164ETH).
Audio Alarm Verification
Connections (AAV, “Listen-In”)
Refer to the connection diagram below.
Connections use one of the on-board triggers.
Suggested AAV Module:
ADEMCO UVS (shown) or Eagle 1250
Notes
•
Set field *91 for AAV and program the
appropriate output (output 17 or 18) using
*80 Menu mode (select zone type “60”).
•
For voice session monitoring, connect an
EOLR zone to UVCM module terminals 6 &
7, and program the zone as zone type 81 (*56
Menu mode).
E.g., Using output 18 for the trigger, program
an output function in *80 Menu mode as:
ZT = 60, P = 0, Action = 1, Device = 18
ON
ON
1
2
345
67
8
1
2
345
67
8
12
3
4
5
6
78
9
1
0
1
1
29
30
31
32
33
34
NOTE:
REFER TO UVCM MODULE
INSTRUCTIONS FOR
CONNECTIONS TO AUDIO
SPEAKERS AND MICROPHONE.
UVCM
MODULE
ZONE
TERMINALS
EARTH
GROUND
RED (R)
GREEN (T)
GREY (R)
BROWN (T)
TRIGGER
CONNECTOR
OUTPUT 18
EOL
RING
TIP
OPTIONAL
MONITORING ZONE
CONNECTION
(USE ZONE TYPE 81)
FALLING VOICE TRIG
GND
+12VDC IN
SWITCH
BANK 2
SWITCH
BANK 1
SWITCH BANK 2
SWITCH BANK 1
AUXILIARY
AUDIO LEVEL
ADJUSTMENT
TRIM POT
aa
v_uvcm-003-V0
CONTROL
INCOMING
PHONE LINE
TO
PREMISES
HANDSET
5
1 = ON
2 = ON
3 = OFF
4 = ON
5 = ON
6 = ON
7 = ON
8 = ON
1 = OFF
2 = OFF
3 = OFF
4 = OFF
5 = OFF
6 = OFF
7 = OFF
8 = ON
23
24
25
+12VDC
GND
4
5
21
22
RJ31X
Figure 13. Connection of AAV Unit