![Honeywell ADEMCO Vista-12C Скачать руководство пользователя страница 82](http://html.mh-extra.com/html/honeywell/ademco-vista-12c/ademco-vista-12c_installation-and-setup-manual_153257082.webp)
Installation and Setup Guide
5-26
Programming Installer and User Schedules
The system provides up to 8 schedules, which can be used to control 12 types of system events
at pre-defined times. 4 schedules are intended for use by the end-user, and 4 are reserved for
the installer. In addition, some events are also reserved for the installer only (listed in the
“Enter Event” prompt paragraph below).
Start Scheduling mode by entering installer code + [#] + [6] [4] while in normal operating
mode.
NOTE:
The master code can only access schedules 01-04 and events 00-08.
The following prompts are displayed:
PROMPT
VALID ENTRIES
EXPLANATION
E N T E R S C H E D N O .
0 0 = Q U I T 0 0
Schedule Number
01-04 = end-user schedules
05-08 = installer-only schedules
[
∗
] to continue
Enter the desired schedule number.
E N T E R E V E N T
NOTE:
Events 07 and 10
cause the keypad to
beep every 30 seconds
when messages are
displayed. Stop the
beeps by user code +
OFF.
Enter Event
00 = clear event
01 = Relay On/Off
02 = User Access
03 = Child Not Home Report to
Pager
04 = Forced Stay Arming
†
05 = Forced Away Arming
†
06 = Auto Disarm
07 = Display “Reminder”
08 = Disarm Time Window
11 = Periodic Test Report
12 = Up and About
[
∗
] to continue
Enter the desired event number for event you
want to occur at a specified time.
Events 10-12 are reserved for the installer only.
Child-Not-Home report (option 03) is sent to all
pagers in the user’s partition (message sent is 777-
7777). User must be enabled for paging (see User
Attributes in
System Operation
section).
Disarm Time Window (08): System can be
disarmed only during this time period. Exception:
If a burglary alarm occurs, the system can be
disarmed outside the scheduled time window.
† Forced bypass is automatically enabled
regardless of setting in field *23.
D E V I C E N U M B E R
X X
Device Number
01-04 = device number
[
∗
] to continue
This prompt appears if event “1” (relay on/off) was
selected, otherwise it is skipped.
Enter the physical device number as programmed
in
∗
79 Menu Mode, then press [*] to continue to
the “Start” prompt.
Device numbers 17 and 18 designate built-in
triggers 1 and 2 respectively.
G R O U P N U M B E R
X
Group Number
1-8 = group number
[
∗
] to continue
This prompt appears if event “2” (user access) was
selected. Otherwise it is skipped.
Press [*] to continue to the “Start” prompt.