Installation and Setup Guide
5-2
PROMPT
VALID ENTRIES
EXPLANATION
Enter Zn Num.
(00 = Quit)
17
Zone Number
wired zones 01-06,
aux wired zones 17-24
wireless zones 09-24
RF button zones 49-64
91 = addr. device report enable
92 = duress report enable
95, 96, 99 =emergency zones
00 to quit
[
∗
] to continue
Enter the zone number that you wish to program.
Zone 17 has been entered as an example in the
display at left.
Enter a report code for zone 91 to enable
addressable device reporting.
Enter a report code for zone 92 to enable duress
reporting.
95, 96, 99 are emergency (panic) key zones.
Zn ZT P RC In: L
17 00 1 10 RF: 1
OR
Zn ZT P RC In: AD
17 00 1 10 AW: 07
OR
Zn ZT P RC HW: RT
17 00 1 10 EL 1
Summary Screen
[
∗
] to continue
A summary display appears.
“IN: L” appears for wireless zones and indicates
input type and loop.
“IN: AD” appears for wired expansion zones (AW)
and indicates the module’s address (AD), which is
based on the zone number.
“HW: RT” appears for basic wired zones and
indicates configuration (EOL, NO, NC, zone
doubling, double-balanced) and response time
selection.