Menu Mode Programming
5-25
PROMPT
VALID ENTRIES
EXPLANATION
9 0 A l m / T r b l P r o c
0
Alarm/Trouble
Processing
0 = none
1 = Zone type has automatic
restore
2 = zone type uses Misc. Fault
Delay Time and automatic
restore
[
∗
] to continue
Select desired actions for zones assigned to this
zone type.
Option 2: Select Miscellaneous Fault Delay in
field *87.
NOTE:
If 6 was selected above for the Zone
Attribute, enter 0 for this prompt.
9 0 T R B L S O U N D
0
Trouble Sounding
0 = none
1 = one beep every minute
2 = normal trouble sound (fast
beeps)
[
∗
] to continue
Select type of sounding upon trouble conditions on
zones assigned to this zone type.
9 0 A L A R M S O U N D
0
Alarm Sounding
0 = none
1 = keypad sound only
2 = steady siren sounding
3 = pulsing siren (temporal)
[
∗
] to continue
Select type of sounding upon alarm conditions on
zones assigned to this zone type.
9 0 D i a l D e l a y
0 = N o , 1 = Y e s
Dial Delay?
0 = no
1 = yes
[
∗
] to continue
If selected, faults on zones assigned to this zone
type will delay reporting for whatever length of
time that is selected in dial delay (*50).
9 0 D i s p O p t i o n
1
Display Options
0 = no display
1 = display only
2 = chime only
3 = chime & disp.
[
∗
] to continue
Select whether faults on zones assigned to this
zone type are displayed at the keypad and/or
cause a chime sound.
A l a r m I D : 0 0 0
T r o u b l e I D : 0 0 0
Contact ID Report Codes
000-999 = report code
[
∗
] to continue; returns to Enter
configurable zone type number
prompt.
Enter the desired 3-digit Contact ID report codes
for faults and troubles occurring on zones assigned
to this zone type.
IMPORTANT:
•
Make sure the code does not conflict with
existing, predefined Contact ID report codes.
See the
System Communication
section for a
list of standard Contact ID codes.
•
Zone alarm report code (prompt in *56 Zone
Programming) and Trouble report code (*60)
and relevant restore codes (*70, *71) must be
enabled in order for the Configurable Zone Type
codes to be reported.