ACUIX High Speed Dome User Manual
Document 800-01023 Rev A
25
02/08
VCL - RS485
For VCL - RS485 protocol, the commonly used setting is 9600 baud, no parity.
SW5 - 11000001 (positions 1–8).
In above SW5–8 is ON to force reading from DIP switches. See
DIP Switch Address
Override
, page
26
, for more information on setting SW5–8.
SW6 - 00100000 (positions 1–8) sets the ACUIX to 9600 baud with no parity.
IntelliBus™
SW5 - 00000001 (positions 1–8).
In above SW5–8 is ON to force reading from DIP switches. See
DIP Switch Address
Override
, page
26
, for more information on setting SW5–8.
SW6 - 01100000 (positions 1–8) sets the ACUIX to 38400 baud with no parity.
Camera Address Settings
Address selection is via rotary switches SW1, SW2, SW3, and SW4.
Caution
The ACUIX can be addressed from 0000 to 9999. The addressing
scheme may be restricted due to the limitations of the controller
being used to control the ACUIX. For example, the
HEGS5000/HEGS5001 controllers can control camera addresses 1
to 256. The HJZTP can control camera addresses 1 to 128.
Table 2-4
ACUIX Camera Addresses
Address
Value
SW1
Units digit
SW2
Tens digit
SW3
Hundreds digit
SW4
Thousands digit
Содержание ACUIX
Страница 1: ...Document 800 01023 Rev A 02 08 User Manual ACUIX High Speed Dome ...
Страница 10: ...Rev A Document 800 01023 02 08 Contents 10 ...
Страница 12: ...Rev A Document 800 01023 02 08 Figures 12 ...
Страница 28: ...28 Switch Settings ...
Страница 74: ...74 Operation and Programming with Honeywell VCL Protocol ...
Страница 78: ...78 Operation and Programming with IntelliBus Protocol ...
Страница 132: ...132 Troubleshooting ...
Страница 138: ...138 Specifications ...
Страница 140: ...140 Pelco Emulation ...
Страница 142: ...142 Digital Video Recorder Integration ...
Страница 147: ......