Mimic Tours
Sixteen (16) Mimic Tours up to 120 seconds each can be programmed in each ACUIX. A
Mimic Tour stores the manual commands (pan, tilt, and zoom) performed by an operator.
A tour can be recalled by an operator, activated in response to an alarm, or programmed
as the default function when the ACUIX is idle for a specified time.
Program Mimic Tours
Note
Mimic Tour programming is only available to a user logged in on the
HEGS5000/5001 controller as the Master user.
Method 1: HEGS5000 LCD (Tours 1–3)
1.
Press Dome Menu.
2.
Press + or - until
Tour Menu
displays on the controller LCD.
3.
Press Enter.
4.
Press + or - until
Program
displays on the controller LCD, and press Enter.
5.
Enter the Mimic Tour number (1–3) you desire to program using the numeric keypad
on the controller and press Enter. The controller LCD displays
Tour Prgrm Stop
.
6.
The ACUIX begins to count down from 120 to 0 seconds. Perform the desired pan, tilt,
and zoom commands until the ACUIX times out. The ACUIX saves all commands as
the operator performs them. To end the programming before the ACUIX times out,
press Enter (
Tour Prgm Stop
) or press Clear/Manual.
A message
PROGRAM MIMIC TOUR COMPLETE
displays on the monitor.
Method 2: On-Screen Setup Menu
See
Mimic Tour (Honeywell Diamond Protocol Only)
, page
116
, in
Chapter 7, On-Screen
Setup Menus
for more information on setting up Mimic Tours.
Run Mimic Tour
Caution
Continuous Mimic Tour operation (no times with zero motion and
autofocus set on pan, tilt, and zoom) is not recommended.
Continuous operation results in increased zoom lens failure and
maintenance expense. Similarly, avoid setting auto focus to
continuous.
Содержание ACUIX
Страница 1: ...Document 800 01023 Rev A 02 08 User Manual ACUIX High Speed Dome ...
Страница 10: ...Rev A Document 800 01023 02 08 Contents 10 ...
Страница 12: ...Rev A Document 800 01023 02 08 Figures 12 ...
Страница 28: ...28 Switch Settings ...
Страница 74: ...74 Operation and Programming with Honeywell VCL Protocol ...
Страница 78: ...78 Operation and Programming with IntelliBus Protocol ...
Страница 132: ...132 Troubleshooting ...
Страница 138: ...138 Specifications ...
Страница 140: ...140 Pelco Emulation ...
Страница 142: ...142 Digital Video Recorder Integration ...
Страница 147: ......