ACUIX High Speed Dome User Manual
Document 800-01023 Rev A
103
02/08
Note
Clearing the memory does not clear the language selection or programmed
Privacy Zones.
Note
When using Diamond protocol and a HJZTP controller you cannot clear the
memory from the Clear Memory menu.
Clear the Error Table
Select 4 to Clear the Error Table.
The ACUIX keeps track of the last 64 bytes
of errors and events that occurred during
operation of the unit. Selecting 4 clears the
table.
Display Error Table Codes
Select 5 from the Diagnostic Options menu
to display a list of the error and event table
codes.
ERROR TABLE HAS BEEN CLEARED
Error and Event Codes
00 - Corrupted memory
01 - Proc low voltage reset
02 - Proc bus error
03 - Proc address error
04 - Proc illegal instruction
05 - Proc zero divide
06 - Proc privilege violation
07 - Proc spurious interrupt
08 - Four ESC reset
09 - Pan motor error
10 - Corrupted data to camera
11 - Camera data queue overrun
21 - Command queue overrun
22 - Packet framing error
C0 - Receive queue overrun
Cx - bit0-Byte parity error
bit1-Byte framing error
bit2-Byte noise error
bit3-Byte overrun error
D0 - Byte timeout error
D8 - Packet parity error
EE - RESET, following byte
gives type of reset
bit1-System Reset
bit2-Loss of Clock Reset
bit4-Bus Fault Reset
bit5-Watchdog Reset
bit6-Power ON Reset
bit7-External Reset
Содержание ACUIX
Страница 1: ...Document 800 01023 Rev A 02 08 User Manual ACUIX High Speed Dome ...
Страница 10: ...Rev A Document 800 01023 02 08 Contents 10 ...
Страница 12: ...Rev A Document 800 01023 02 08 Figures 12 ...
Страница 28: ...28 Switch Settings ...
Страница 74: ...74 Operation and Programming with Honeywell VCL Protocol ...
Страница 78: ...78 Operation and Programming with IntelliBus Protocol ...
Страница 132: ...132 Troubleshooting ...
Страница 138: ...138 Specifications ...
Страница 140: ...140 Pelco Emulation ...
Страница 142: ...142 Digital Video Recorder Integration ...
Страница 147: ......