22
Switch Settings
Protocol Settings
DIP switch SW5 is used to select the protocol setting for your ACUIX. See
Table 2-1
for
more information. The default protocol setting for the ACUIX is the Honeywell Diamond
protocol.
Note
If there are invalid settings on SW5 or SW6 regarding protocol or baud rate,
the system defaults to Diamond protocol at 9600 baud rate.
Table 2-1
DIP Switch SW5 ACUIX Protocol Settings
Protocol Name
Switch Position
1
2
3
4
5
6
7
8
IntelliBus™
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
Diamond
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
MAXPRO Mode
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
VCL - RS485
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
VCL Video Telemetry
(Control over Coax)
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
Pelco P
ON
OFF
ON
OFF
OFF
OFF
OFF
OFF
Pelco D
OFF
ON
ON
OFF
OFF
OFF
OFF
OFF