Preset Tours
Sixteen Preset Tours (1–16) can be programmed for each ACUIX. Up to 64 Presets, with
velocity settings and dwell times for each Preset, can be programmed into every Preset
Tour. Preset Tours can be started by an operator, started in response to an alarm, or
programmed as a default function when the ACUIX is idle for a specified amount of time.
When an ACUIX receives a command to run a Preset Tour, the ACUIX goes to the first
Preset programmed in the Preset Tour at maximum velocity (480°/second) and remains at
the Preset for the programmed dwell time, then goes to the next Preset in the Preset Tour
at the programmed velocity and remains at that Preset for the specified dwell time, and so
forth for all other programmed Presets.
When an operator runs a Preset Tour continuously, the ACUIX goes from the last Preset to
the first Preset at the programmed velocity. The amount of time the ACUIX takes to go to
each Preset depends on the programmed velocity and the distance to the next Preset’s pan
and tilt coordinates. The velocity is programmable from 1° to 480° per second. The title of
each Preset, as it is viewed, is added to the video signal. For the title to be displayed on the
monitor, Preset Titles must be set to ON. The Preset Tour repeats continuously until an
operator manually controls the ACUIX (pan, tilt, zoom, focus, or iris) or the ACUIX receives
a Preset, Preset Tour, Mimic Tour, or find home command.
When an operator runs a Preset Tour once, the ACUIX goes to each Preset programmed
as defined above for continuous operation. When the ACUIX executes the last Preset, it
automatically stops the Preset Tour.
Program Preset Tours
Note
Preset Tour programming is only available to a user logged in as the Master
user on the HEGS5000/HEGS5001 controller.
1.
Press Dome Menu.
2.
Press + or - until
VectorScan Menu
displays.
3.
Press Enter.
4.
Press + or - until
Program
displays.
5.
Press Enter. Follow the on-screen prompts that appear on the monitor where the
ACUIX video is viewed.
6.
Enter the Preset Tour number (1–16) using the numeric keypad and press Enter. If
the selected Preset Tour number has already been programmed, the title displays
and the programmed Presets are displayed. To accept the existing title, press Enter.
To change the current title, proceed to step 7.
Note
Preset Tours 1– 16 can be programmed from the HEGS5000 controller.
7.
Enter the desired title by performing the following steps:
Содержание ACUIX
Страница 1: ...Document 800 01023 Rev A 02 08 User Manual ACUIX High Speed Dome ...
Страница 10: ...Rev A Document 800 01023 02 08 Contents 10 ...
Страница 12: ...Rev A Document 800 01023 02 08 Figures 12 ...
Страница 28: ...28 Switch Settings ...
Страница 74: ...74 Operation and Programming with Honeywell VCL Protocol ...
Страница 78: ...78 Operation and Programming with IntelliBus Protocol ...
Страница 132: ...132 Troubleshooting ...
Страница 138: ...138 Specifications ...
Страница 140: ...140 Pelco Emulation ...
Страница 142: ...142 Digital Video Recorder Integration ...
Страница 147: ......