ACUIX High Speed Dome User Manual
Document 800-01023 Rev A
129
02/08
Problem: Video, But No Control
1.
Ensure the controller is addressed to the correct ACUIX unit. Each unit has a unique
camera address used for controlling it.
2.
Ensure the three rotary switches on the receiver board are set to the proper camera
number (address).
SW1 - units digit
SW2 - tens digit
SW3 - hundreds digit
SW4 - thousands digit
3.
Ensure DIP switches SW5 and SW6 are set for the correct protocol, baud rate, and
parity. The ACUIX must be set the same as the control equipment.
4.
Power down all system components for 15 seconds and then re-apply power to
reset the ACUIX. Manually control the ACUIX and verify that the ACUIX finds home.
5.
Wiring:
a.
Make sure that the data wiring is connected at the terminal strip in the housing.
b.
Make sure that any bare wires are not touching each other.
c.
Make sure that the wire insulation is stripped back far enough for a good
connection.
6.
If there are multiple ACUIX units in the system, exchange the pan and tilt camera
assembly in question with a pan and tilt camera assembly from another housing.
Set the address of the exchanged camera assembly to the existing unit. Call up the
ACUIX at the controller. If control returns, the problem is isolated to the pan and tilt
camera assembly.
Содержание ACUIX
Страница 1: ...Document 800 01023 Rev A 02 08 User Manual ACUIX High Speed Dome ...
Страница 10: ...Rev A Document 800 01023 02 08 Contents 10 ...
Страница 12: ...Rev A Document 800 01023 02 08 Figures 12 ...
Страница 28: ...28 Switch Settings ...
Страница 74: ...74 Operation and Programming with Honeywell VCL Protocol ...
Страница 78: ...78 Operation and Programming with IntelliBus Protocol ...
Страница 132: ...132 Troubleshooting ...
Страница 138: ...138 Specifications ...
Страница 140: ...140 Pelco Emulation ...
Страница 142: ...142 Digital Video Recorder Integration ...
Страница 147: ......