Chapter 10 Program Example
2
Pnet I/F Module 2MLL-PSRA, 2MLL-PMEA, 2MLL-PMEB User
’s Guide
R220
Honeywell
January 2019
10.1.1 SyCon settings
It is convenient for the user to prepare data Send/Receive map as in [Table 10.1.1] in order to exchange
data in the system as shown on [Fig.10.1.1]. After SyCon Configuration is set for data Send/Receive as in
[Table10.1.1], High-speed link parameters shall be specified and downloaded to PLC.
Firstly open the
‘New’ file in the SyCon and Screen is exchanged for setting screen after PROFIBUS
chosen in
‘Select Fieldbus’ window.
[Figure 10.1.2] The first communication types (PROFIBUS)
After communication types chose, Select Master type as COM-C-DPM, 2MLL-PMEA master board. Add
COM-C-DPM and then set station address of master module.
[Figure 10.1.3] master module type settings