Operation Requirements:
Primary propane shut-off valve on the
propane tank is open.
House batteries are charged.
House battery disconnect switch is on.
Battery cut-off switch is on.
Thermostat
There is a short time delay before the blower
motor begins. When interior temperature
reaches the thermostat set point, the burner
will extinguish. The blower motor will
continue to run for two or three minutes to
cool down the furnace.
- Standard Roof A/C:
Set System switch to Heat.
Set temperature to desired setting.
- Roof A/C with Heat Pump:
Set System switch to Heat.
Press the Zone button repeatedly to
select desired zone.
Press the Mode button repeatedly until
Gas is displayed.
Set desired temperature by pressing the
Up or Down buttons.
Repeat process for each desired zone.
CAUTION:
Do not store any items or materials in
the furnace area. Restricted air flow
may hamper furnace operation leading
to failure and/or fire hazard.
NOTE:
The automatic ignition circuit board
will attempt to light the burner three
times before the ignition board will
go into “lock-out.” If lock-out occurs,
the blower will continue to operate
until the thermostat is turned off.
Once the blower motor stops, turn
the thermostat back on to reset the
ignition cycle.
Furnace Tips:
Operation of the furnace may produce
a musty smell during the first couple of
cycles after the motorhome has been
removed from storage.
Operating the furnace at altitudes
above 5,000 feet reduces the BTU
output due to air/fuel ratio.
Have the furnace periodically serviced
by a qualified technician, especially if
the system exhibits unusual symptoms
such a noise or a foreign odor.
If the Furnace Fails to Light
Make sure the primary propane shut-off
valve is open.
The furnace will not light if the blower
motor is not spinning to specified speed.
This may be due to a low house battery
charge condition.
To Charge the House Batteries:
Hook-up to shore power, start the
generator, or start the motorhome.
If the blower motor fails to operate after
verifying the batteries are charged and the
fuses are good, use a screwdriver or coin to
open the furnace access panel outside of the
motorhome.
Example of furnace
screen.in Zone 1.
031359a
031063k
Set thermostat to heat mode
Adjust temperature setting
031358
Содержание Trip 2012
Страница 1: ...2 0 1 2 B YHOL I D A YR A MB L E R O w n e r s Ma n u a l...
Страница 13: ...Notes...
Страница 45: ...40 Driv ing Safety 2 2012 Trip Weight Record Sheet...
Страница 51: ...46 Driv ing Safety 2 2012 Trip Notes...
Страница 138: ...133 W ater Sy stems 6 2012 Trip Water System Diagram 040487va...
Страница 139: ...134 Wat er Sy stems 6 2012 Trip Notes...
Страница 151: ...146 Pro p ane Sy tems 7 2012 Trip Notes...
Страница 173: ...168 Ho us e Electr ical 8 2012 Trip Notes...
Страница 190: ...185 Chassis Electrical 9 2012 Trip Engine No Start Flow Chart...
Страница 191: ...186 Ch as s is Electr ical 9 2012 Trip Notes...
Страница 237: ...232 Ch assis 10 2012 Trip Notes...