Maintenance
Light bulbs need to be replaced when you notice a dark section of the flame or when the clarity and detail of
the log exterior disappears. There are two bulbs at the top of the opening which illuminate the log set exterior, and
four bulbs under the log set which generate the flames and embers.
WARNING:
Turn OFF circuit beaker before attempting any maintenance or cleaning to reduce the risk
of fire, electric shock or damage to persons.
NOTE:
Allow at least 5 minutes for light bulbs to cool off before touching bulbs to avoid accidental
burning of the skin.
To Open the Light Bulb Area:
• Remove the rim by pulling straight forward.
• Hold glass in place while removing retaining top clip.
• Lift glass out and store in a safe place.
CAUTION:
Even though the glass is safety glass it may break if bumped, struck or dropped. Care must
be taken when handling the glass.
WAter HeAter
The gas/electric water heater is designed to operate with minimum maintenance. Fill the tank with water
before powering the heater, to avoid damage to the unit. Problems with the electric water heater may occur when
the heater is powered before the tank is filled with water.
The Water Heater Will Heat Water Using Two Different Methods:
1. 120 Volt AC, supplied by shore power - The 120 Volt AC uses a heating element similar to that of a water
heater typically found in a house. The 120 Volt AC method is efficient if shore power is available.
2. LP-Gas - The LP-Gas incorporates the use of an automatic ignition circuit board operated by 12 Volt DC.
Two thermostats control the water temperature: One for the 120 Volt and the other for the LP-Gas. The water
heater manufacturer presets the temperature of both thermostats.
Water is pumped into the bottom of the water heater tank and is heated using LP-Gas, 120 Volt AC, or a
combination of both. The heated water is discharged out of the top of the tank upon usage.The water heater is
equipped with a bypass valve for easy winterization and a
Temperature Pressure Relief Valve
for safety. The
water heater has an aluminum-clad tank; therefore, an anode is not necessary.
NOTE:
Do not operate the water heater by either function without water in the water heater tank.
This can damage the thermostats and the electric heating element.
NOTE:
The automatic ignition circuit board will make three attempts to light the burner. If the
burner does not light by the third attempt, the ignition circuit board will go into lock-out.
Cycling the on/off switch will reset the ignition board.
Содержание Savoy LX 2006
Страница 4: ......
Страница 10: ......
Страница 12: ......
Страница 14: ......
Страница 42: ...42 Section 2 2006 Driving Safety Savoy SL LX 5thWheel TravelTrailer Weight Label 100179f...
Страница 47: ...Savoy SL LX 5thWheel TravelTrailer 2006 Driving Safety Section 2 47 Four Tire Weighing...
Страница 52: ......
Страница 66: ......
Страница 92: ......
Страница 108: ......
Страница 122: ......
Страница 132: ......
Страница 144: ...144 Section 8 Electrical Systems Savoy SL LX 5thWheel TravelTrailer Metric U S Conversion Chart...
Страница 147: ...Savoy SL LX 5thWheel TravelTrailer 2006 Electrical Systems Section 8 147...
Страница 149: ...Savoy SL LX 2006 Index...
Страница 150: ......