135 (148)
•
DHCP configuration renewed at Ethernet (
<interface index>
).
The run time system has renewed its IP configuration for the Ethernet interface with the
given index from the DHCP server.
•
DHCP configuration completed at Ethernet (
<interface index>
).
The run time system has gotten a new IP configuration for the Ethernet interface with the
given index from a DHCP server.
•
Could not initialise power fail handling.
The power fail handling could not be initialised. It will not be possible to store data
retentively.
•
Power fail condition present at start-up
A power fail condition was already present at start-up. Probably the device's supply voltage
is insufficient.
•
Retentive data could not be loaded.
Retained data (e.g. portal variables) could not be loaded although the device is equipped
with a power fail circuit. This message is normal at the very first start-up of the device. If it
occurs later, there is probably a problem with the power fail circuit.
•
Not enough power fail capacity
The device is equipped with a power fail circuit, but the capacity supplied is not sufficient to
store data (e.g. portal variables) retentively. This should not happen.
•
Power fail handling not supported
The device is not equipped with a power fail circuit. Data (e.g. portal variables) cannot be
stored retentively.
•
The internal flash drive seems to be weak.
A write operation to the internal flash drive needed to be retried several times. This is an
indication for the flash drive reaching the end of its life.
•
Flash write error. The internal flash drive is probably defect.
A write operation to the internal flash drive failed. The flash drive seems to have reached
the end of its life. The device is no longer usable.
•
Could not create directory structure on external medium
The required directory structure could not be created on the external medium.
•
One or more certificates could not be loaded.
At least one of the SSL certificate files could not be loaded.
•
Could not initialise NAT/firewall service. (
<error code>
)
The NAT and firewall service could not be initialised. The message also shows an internal
error code returned by the service's initialisation routine.
•
Could not start Ethernet (1) driver.
The driver for the second Ethernet interface could not be started.
•
Unsupported Ethernet (1) interface type. (
<interface type>
)
The HMS Hub firmware could not find a driver for the second Ethernet interface. The
message also shows the numerical Ethernet interface type.
Anybus Edge Gateway Reference Guide
SCM-1202-154 1.0 en-US