103 (148)
T1
Timeout of send or test APDUs in seconds
T2
Timeout after which an S frame will be sent in seconds
T3
Timeout after which a test frame will be sent in case of long idle state in seconds
TCP Port
TCP port number
Short Pulse Time
Short Pulse Time in milliseconds
Long Pulse Time
Long Pulse Time in milliseconds
Buffer Size
Number of events that are stored and will be sent to the client in case of a connection
loss
Maximum number of
connections
Maximum number of clients, that can connect to this server. More than 1 connection
enables also redundant connections.
Generate activation
termination
If true, an activation termination will be generated - e.g. when a pulse command
terminates
Accept clock synchronisation
command
If this option is set, the clock synchronisation command (C_CS, 103) will be accepted
and the time from the client will be transferred to the system clock.
Please note that the clock synchronisation via
IEC 60870-5-104 may conflict with other clock
synchronisation mechanisms. It is
recommended to activate only one clock
synchronisation mechanism.
Please note that the IEC 60870-5-104 Server will only be available if your Edge gateway device
has a valid IEC 60870-5-104 Server licence.
Event Log Messages
The following section describes the messages that the IEC 60870-5-104 Server driver may log to
the Event Log. All messages are prefixed with the text
IEC 60870-5-104 server driver:
.
•
Updated output at address
<information object address>
.
The output with the given information object address has been successfully updated. This
message will only be shown, if updating the same output has failed before.
•
The interval is being maintained again.
This message appears after this message, when the interval is being maintained again.
•
Timestamps with 16 or 24 bit are not yet supported. Falling back to system time..
Timestamps with size 16 bit or 24 bit are not supported in this version.
•
A cyclic transmission time of types 1, 3, 5, 7, 30, 31, 33, 34 and 36 is no longer supported
and has been converted to 0.
A cyclic transmission time of the following types is no longer supported and has been
converted to 0. To permanently remove this warning, you have to save the current IEC
60870-5-104 server configuration.
–
Single-point information (1)
–
Double-point information (3)
–
Step position information (5)
–
Bitstring of 32 bit (7)
–
Single-point information with time tag CP56Time2a (30)
–
Double-point information with time tag CP56Time2a (31)
–
Bitstring of 32 bit with time tag CP56Time2a (33)
–
Measured value, normalized value with time tag CP56Time2a (34)
–
Measured value, short floating point value with time tag CP56Time2a (36)
Anybus Edge Gateway Reference Guide
SCM-1202-154 1.0 en-US