133 (148)
7
System Start-up
At start-up, the HMS Hub firmware will go through several steps in order to bring the system into
operation.
•
Check if there is an update package to be installed
•
Check for factory reset request
•
Load configuration data
•
Initialise I/O hardware
•
Initialise PLC and sidekick components (Cellular Modem driver, Firewall etc.)
•
Load program
•
Set up web services
•
Start program
•
Supervise components
7.1
Event Log Messages
The following section describes the messages that the firmware may log to the Event Log at
start-up or possibly at a later time. All Messages are prefixed with the text
Run Time System:
.
•
Started
The firmware has just been started.
•
Portal communication module initialised
The portal communication module has been successfully initialised.
•
I/O hardware manager initialised
The I/O hardware manager that manages the physical I/O hardware has been successfully
initialised.
•
NAT/firewall service initialised
The NAT and firewall service has been successfully initialised.
•
Ethernet (1) driver started.
The driver for the second Ethernet interface has been successfully started.
•
Cellular modem driver initialised
The cellular modem driver has been successfully initialised.
•
Remote Update deactivated
The remote update functionality is deactivated.
•
Offline Update deactivated
The offline update functionality is deactivated.
•
Update module initialised
The update module, which manages the loading and programming of update packages, has
been successfully initialised.
•
PLC driver initialised
The PLC driver has been successfully initialised.
Anybus Edge Gateway Reference Guide
SCM-1202-154 1.0 en-US