86 MISC. OPTIONS
868 Auto Hr Change
869 Wrk 2 EN50131
860 Silent Fire
867 Int Bell Chime
866 Latch Chime
865 Sys Dbl Knock
864 Walk Tst Bell
863 Duress Codes
862 Eng. Lock
861 Timed Soak
Used to select miscellaneous system options.
When
Timed Soak
is enabled all zones and points with the
Soak option enabled will remain in soak until the
Soak Period
(refer to
Timers Menu
) has expired i.e. reached 0.
When
Eng. Lock
is enabled the panel can only be returned to
default settings through the
Service Menu
(
Default Panel
).
Powering down the panel and pulling the factory settings link
before powering up will not default the panel back to factory
settings.
When
Duress Codes
is enabled valid user codes + 1 will
generate a duress alarm e.g. If User 1 has code 06788 and
enters code 06789 then a duress alarm will be generated i.e. a
silent PA
Walk Tst Bell
when enabled will sound the internal bells as
well as keypad buzzers during walk test in the
Service Menu
.
If disabled then only the Rkp buzzers will sound for activations
in engineer walk test.
When
Sys Dbl Knock
is enabled any two zones with the
Dbl
Knock
option enabled activating within the double knock reset
period will generate an alarm. Note that the same zone
activating twice within the double knock reset period will also
generate an alarm.
When
Latch Chime
is enabled the chime mode is not cleared
when the panel is armed. If disabled then the Chime mode is
always turned off when the panel is armed.
If
Int Bell Chime
is enabled then the internal bell will also
sound in the event of a system chime i.e. a zone with chime
option opening when the panel is unset.
When
Auto Hr Change
is enabled the time in the panel will
advance by 1 hour for Summertime and go back by one hour
for Wintertime.
When
Wrk 2 EN50131
is enabled, the system will invoke
EN50131 features that are not normally programmable e.g.
entering the engineer code with user code authorisation.
When
Silent Fire
is enabled the internal and external bells do
not activate. However, a fire message is still displayed on the
keypad and a message sent to the monitoring station.
System Options Menu - Continued
84
Default Eng. Code - 4567 Default User Code - 1111 (Irl) 1234 (UK)
Содержание SW-1070
Страница 1: ... for V3 3 Software www hkcsecurity com Security Safe Secure SecureComm compatible Installation Manual ...
Страница 117: ...Default Eng Code 4567 Default User Code 1111 Irl 1234 UK Appendix B 117 GPRS GSM SMS DATA Voice ...
Страница 118: ...Broadband SMS DATA or Appendix B Default Eng Code 4567 Default User Code 1111 Irl 1234 UK 118 ...
Страница 120: ...Default Eng Code 4567 Default User Code 1111 Irl 1234 UK 120 Appendix Appendix Appendix B SMS Voice Standard Mobile ...