Mains Dly
Alarm Abort
Pre-Alarm
Tech1 ... 8
Fire Exit 1 ... 12
Trouble
Buzzer
Tamper
Perimeter
FireReset
Latch
PartSet
The PartSet output is activated after the panel has been partially set or armed. It is
deactivated when the system is unset.
The Latch output type is normally at 0V. At the start of Exit Time it switches from 0V to HIGH
and stays HIGH until the system is unset.
The FireReset output is normally at 0V. In the event of a fire alarm,
the FireReset output will
go HIGH for 2 seconds the next time the panel is armed. The FireReset output also switches
HIGH for 2 seconds after exiting Engineer Mode and 15 seconds after an alarm activation in
the Walk Test Menu.
The Perimeter output is deactivated when the panel is unset. Assuming the system is
armed and a zone has the Perimeter option, the output will activate when that zone has
either a pulse or gross alarm. The output will deactivate when the panel rearms.
Tamper output activates when there is a tamper activation. This output deactivates with a
valid user code.
The buzzer output follows the state of the buzzer on the keypads i.e. active when the buzzer
is on and not active when the buzzer is off.
The Trouble output activates when there is a fault or tamper on the system e.g. mains fail,
line fault, low battery etc. It deactivates when the fault or tamper clears.
The Technical outputs (1-8) follow the state of their respective Technical inputs i.e. normally
deactivated when their associated zone is closed and active when the zone is open.
The Fire Exit outputs (1-12) follow the state of their respective Fire Exit inputs (like Technical
inputs) but with added features like a delay time, user code intervention, internal bell option
etc. They are normally deactivated when their associated zone is closed and active when
the zone is open
Pre-alarm output triggers when the 1st alarm zone activates. It deactivates at disarm or at
the end of the Alarm Abort Time. This is known as
Intruder
in the UK.
Alarm Abort output activates if there has been a pre-alarm followed by a disarm during the
Alarm Abort Time. It deactivates at disarm or at the end of the Alarm Abort Time.
The Mains Delay output will activate when there is a mains failure which exceeds the Mains
Fault Delay Time (programmed in Misc. Timers). It will deactivate when the mains electricity
is restored.
The Unexpected Open event timer is used as a flag if a premises is opened outside of
programmed time limits. An Unexpected Open output will activate if the panel is in an unset
state at end of closing time (i.e. Close Finish time). The output remains in this state until it is
armed, or the start of opening time (i.e. Open Start time) is reached.
The Unexpected Close event timer is used as a flag if a premises is closed outside of
programmed time limits. An Unexpected Close output will activate if the panel is in an armed
state at end of opening time (i.e. Open Finish time). The output remains in this state until it
is unset, or the start of closing time (i.e. Close Start time) is reached.
A typical set-up for a shop might be; Open Start = 7:00, Open Finish = 9:00, Close Start =
17:30 & Close Finish = 18:30 (Monday - Saturday)
The Auto Activate event timer is used outside of normal business hours to trigger an alarm
should the premises remain open longer than the programmed Interval Time. When the
panel is unset by a non-24hour user (e.g. a cleaner) it must be re-armed within the Interval
Time or the output will activate and the panel will go into alarm.
The User Alert timer is used as a checking mechanism to ensure a user is still on the
premises (e.g. a night watchman). Between the Start Time and End Time the user must
check-in with the panel within a specified Interval Time. Each time they check-in the timer is
reset to the interval time. If the timer runs for the full interval without a check-in then the
User Alert output type will activate. This feature only works on the Days programmed to
YES. In order to remind the user to check-in, the keypad will start beeping when the timer
has 2 mins to run. Users will check-in by keying-in 0*5 followed by their user code.
UnexClose
AutoActiv8
UserAlert
UnexOpen
Outputs Menu - Continued
Default Eng. Code - 4567 Default User Code - 1111 (Irl) 1234 (UK)
76
Содержание SW-1070
Страница 1: ... for V3 3 Software www hkcsecurity com Security Safe Secure SecureComm compatible Installation Manual ...
Страница 117: ...Default Eng Code 4567 Default User Code 1111 Irl 1234 UK Appendix B 117 GPRS GSM SMS DATA Voice ...
Страница 118: ...Broadband SMS DATA or Appendix B Default Eng Code 4567 Default User Code 1111 Irl 1234 UK 118 ...
Страница 120: ...Default Eng Code 4567 Default User Code 1111 Irl 1234 UK 120 Appendix Appendix Appendix B SMS Voice Standard Mobile ...