RF-PIR - Continued
Range of Detection
Specifications
2m
2m
2.4m
2.4m
2m
4m
6m
8m
10m
14m
2m
4m
6m
8m
2m
4m
6m
8m
Vertical Coverage
Vertical Coverage
Horizontal Coverage
12m
1m
1m
2m
4m
6m
8m
10m
12m
14m
10m
2m
2m
4m
(close-in detection)
(close-in detection)
Horizontal Coverage
Note: mount the unit 2.4m from the ground
Current Consumption
Battery Life
Range
Frequency
Temperature
Mounting Height
Weight
Dimensions
EN 50131-2-2
3Vdc nom. • 1400mAh • size 2/3A
Standby:
8µA
Transmit:
40mA (peak)
Typically >3 years
Line-of-sight > 400m
868Mhz
2.4m
-10°C to +40°C
W=64mm H= 117mm D = 53mm
155g (including battery)
Grade 2 Class II
Battery
Default Eng. Code - 4567 Default User Code - 1111 (Irl) 1234 (UK)
14
Содержание SW-1070
Страница 1: ... for V3 3 Software www hkcsecurity com Security Safe Secure SecureComm compatible Installation Manual ...
Страница 117: ...Default Eng Code 4567 Default User Code 1111 Irl 1234 UK Appendix B 117 GPRS GSM SMS DATA Voice ...
Страница 118: ...Broadband SMS DATA or Appendix B Default Eng Code 4567 Default User Code 1111 Irl 1234 UK 118 ...
Страница 120: ...Default Eng Code 4567 Default User Code 1111 Irl 1234 UK 120 Appendix Appendix Appendix B SMS Voice Standard Mobile ...