620 Dbl.Nok Open
629 Dbl.Nok Reset
628 Bell Delay
627 Soak Period
626 Split Entry
625 Exit Time
624 Entry Time
623 Strobe Time
622 External Bell
621 Internal Bell
62 SYSTEM TIMERS
(Mins)
(Mins)
(Mins)
(Secs)
(Secs)
(Secs)
(Days)
(Mins)
(Mins)
(Secs)
This menu is used to program timers in the control panel. To
edit a time select it using the
PREV
or
NEXT
keys then press
YES
. Enter the new time to be used. The new time will then be
programmed. Most of the timers are self explanatory but there
are a two things to note....
Note 1:
Split Entry
time is an EN 50131-1 feature. If at the end of the
entry time the system has not been unset it will only activate the internal siren
and the
Split Entry
time starts. Then at the end of the
Split Entry
time, if the
system still has not been unset, both internal and external sirens will activate
and a message sent to the monitoring station (usually this message happens
after a further 20 second delay - or 30 seconds in UK).
Note 2:
“
Dbl. Nok
” is shorthand for Double Knock
.
Zones with the
Double Knock feature need to be activated twice within the
Dbl.Nok Reset
period before they are flagged. Or, they need to remain activated for the
duration of the
Dbl.Nok Open
period before they are flagged
633 Mains Flt Dly (Mins)
632 Fire Exit Delay (Secs.)
631 Wks 2 Service (Weeks)
63 MISC. TIMERS
Wks 2 Service
menu is used to program the number of
weeks between system services. When the
service period
expires,
Service Due
...
Contact Engineer
will be displayed,
as a
prompt to the user, everytime the system
is unset.
Note that p
rogramming "00" disables this
feature
.
Fire Exit Dly;
you can delay the effects of opening a fire exit
door by selecting a delay period here (in seconds).
Mains Flt Dly
;
During a power blackout, a mains fault will
only be re
p
orted to a Central Station if it
exceeds the mains
fault delay period that is
programmed.
Note:
Delays SMS and voice reporting also
64 BLOCK TIMERS
This is where you can adjust the Entry Time, Exit Time,
Internal and External Siren Times for each block.
A block is a
semi-autonomous alarm system within the overall system.
Timers Menu
61 SET DATE & TIME
Used to set the system date and time. The date follows the
following format dd/mm/yy i.e. Day/ month /year and the time is
in 24Hr format as follows hh:mm i.e. Hours : minutes.
Note:
You will be prompted to key-in the time and date when you initially
power-up your system
!
!
!
!
Default Eng. Code - 4567 Default User Code - 1111 (Irl) 1234 (UK)
68
Содержание SW-1070
Страница 1: ... for V3 3 Software www hkcsecurity com Security Safe Secure SecureComm compatible Installation Manual ...
Страница 117: ...Default Eng Code 4567 Default User Code 1111 Irl 1234 UK Appendix B 117 GPRS GSM SMS DATA Voice ...
Страница 118: ...Broadband SMS DATA or Appendix B Default Eng Code 4567 Default User Code 1111 Irl 1234 UK 118 ...
Страница 120: ...Default Eng Code 4567 Default User Code 1111 Irl 1234 UK 120 Appendix Appendix Appendix B SMS Voice Standard Mobile ...