Unused
Line Fault
Inhibit
Force GSM
Zone/Point MAP
Pulse Gate
Heat
Gates
Free to use
Panic Confirmed
Sensor Reset
SmartLight
SmartDoor
A SmartLight output can be set to be triggered by just a zone opening or by just a user code
or it can be set to be triggered by both. An Interval time needs to be programmed and is the
amount of time the light will remain on for when triggered. If a user code is only to be used
to operate a SmartLight, the option for that user should have “Output Only” set to YES.
Note: the time is in minutes.
A SmartDoor output can be set to be triggered by just a zone opening or by just a user code
or it can be set to be triggered by both. An Interval time needs to be programmed and is the
amount of time the door will open for when triggered. If a user code is only to be used to
operate a SmartDoor, the option for that user should have “Output Only” set to YES. Note:
the time is in seconds.
The Unused output has no function and is used to disable an output.
If you have a dialler and the telephone line voltage drops off, the Line Fault output will, after
a short delay, activate. It will also activate if you have a GSM communicator enabled and the
GSM network goes down.
The Inhibit output activates whenever a zone or point is inhibited.
The Force GSM output is used in conjunction with standalone GSM units configured as a
dual path (PSTN & GSM) routers to monitoring stations. Typically wired into the “Force
GSM” input of the router, it toggles between being active and not being active so that both
paths are exercised when the system is doing its regular test call sequence.
This is a special output type that activates in conjunction with mapped zone or point inputs.
See pages 78 and 79.
If a user sends their user code followed by a space and then the word GATE via an SMS
message to their system, a User Output configured as “Pulse Gate” will activate for 5
seconds. This time is programmable.
If a user sends their user code followed by a space and then the phrase HEAT ON via an
SMS message to their system, a User Output configured as “Heat” will activate. HEAT OFF
will deactivate the output.
If a user sends their user code followed by a space and then the phrase GATES ON via an
SMS message to their system, a User Output configured as “Gates” will activate. GATES
OFF will deactivate the output.
If a user sends their user code followed by a space and then the phrase AUX ON via an
SMS message to their system, a User Output configured as “Aux” will activate. AUX OFF
will deactivate the output.
“Free to use” is another User Output and it is configurable. In this example change the
phrase “Free to use” to something more meaningful e.g. PUMP. See page 79. Now if a user
sends their user code followed by a space and then the phrase PUMP ON via an SMS
message to their system, the User Output will activate. PUMP OFF will deactivate the
output. Note also that PUMP 10S will activate the output for 10 seconds, PUMP 10M for 10
minutes, PUMP 10H for 10 hours and PUMP 10D for 10 days.
Note: Heat
,
Gates
and
Aux
can also be renamed in the same way as
Free to use
above.
In the UK, to comply with BS 8243, you may not get a police response unless you activate
two or more hold-up (or panic alarm) devices. When that does happen, the
Panic Conf
output will activate.
If you have an alarm activation and then unset and rearm the system the
SensorReset
output will momentarily activate. Used to clear-down latching detectors.
Outputs Menu - Continued
Default Eng. Code - 4567 Default User Code - 1111 (Irl) 1234 (UK)
Aux
77
!
Содержание SW-1070
Страница 1: ... for V3 3 Software www hkcsecurity com Security Safe Secure SecureComm compatible Installation Manual ...
Страница 117: ...Default Eng Code 4567 Default User Code 1111 Irl 1234 UK Appendix B 117 GPRS GSM SMS DATA Voice ...
Страница 118: ...Broadband SMS DATA or Appendix B Default Eng Code 4567 Default User Code 1111 Irl 1234 UK 118 ...
Страница 120: ...Default Eng Code 4567 Default User Code 1111 Irl 1234 UK 120 Appendix Appendix Appendix B SMS Voice Standard Mobile ...