4
Locate:RF SABB
5
Locate:RF Wand
6
Locate:RF Keypad
2
Wired Devices Menu
1
RF Devices Menu
RF-RKP - continued
4
Remove:RF SABB
5
Remove:RF Wand
6
Remove:RF Keypad
2
Wired Devices Menu
1
RF Devices Menu
•
In the
Locate:RF Keypad
menu you will observe the three LEDs on the front of the RF-RKP in question flash
on and off every second when you select it.
Go to the
Devices Menu
in engineer mode and follow the menu path below...
•
To remove an RF-RKP go to the
Remove:RF Keypad
menu in engineer mode and follow the menu path
below.
•
You will automatically be brought to RF-RKP 1
•
Go to the RF-RKP you want to remove and press
•
Follow the prompts on the display.
Current Consumption
Battery Life
Temperature
Range
Dimensions
Weight
Standards
4x CR123A 3V Lithium batteries (1,400mAh ea.)
Standby:
25µA
Transmit:
40mA
Maximum:
145mA
Typically >3 years
(based on 4 set/unset cycles per day)
Line-of-sight > 400m
-10°C to +40°C
365g
W = 171mm H = 126mm D = 41mm
EN 50131-3 Grade 2 Class II
Battery Supply
Specifications
+12Vdc
0V
!
Note:
When wiring a permanent 12Vdc supply to the RF-RKP please ensure that the battery pack (the
one with the 4 Lithium batteries) IS NOT CONNECTED
Default Eng. Code - 4567 Default User Code - 1111 (Irl) 1234 (UK)
43
Содержание SW-1070
Страница 1: ... for V3 3 Software www hkcsecurity com Security Safe Secure SecureComm compatible Installation Manual ...
Страница 117: ...Default Eng Code 4567 Default User Code 1111 Irl 1234 UK Appendix B 117 GPRS GSM SMS DATA Voice ...
Страница 118: ...Broadband SMS DATA or Appendix B Default Eng Code 4567 Default User Code 1111 Irl 1234 UK 118 ...
Страница 120: ...Default Eng Code 4567 Default User Code 1111 Irl 1234 UK 120 Appendix Appendix Appendix B SMS Voice Standard Mobile ...