1. GETTING STARTED
1-14
Table 1-2 Dimensions, operation and service clearance, and installation clearance
Dimensions (mm)
Operation and
service clearance (mm)
Installation clearance (mm)
Height
Width
Depth
Front
Rear
Left
Right
Front
Rear
Left
Right
93
325
356
500
600
200
200
50
100
10
10
• When you operate the equipment or do maintenance work, provide sufficient clearance, as shown in Figure 1-4.
• The equipment is cooled by fans. The intake holes are on the front and the exhaust holes are on the rear and
sides. Ensure that air flow is not blocked. In particular, leave sufficient clearance in the front (50 mm) and in
the rear (100 mm). (This includes the clearance required for routing cable connectors for the rear side.)
Figure 1-4 Operation and service clearance (top view)
Figure 1-5 Installation clearance
200 mm
200 mm
Front side
Rear side
600 mm
500 mm
Vertical installation (top view)
100 mm
50 mm
10 mm
10 mm
Rear side
Horizontal installation (top view)
100 mm
10 mm
50 mm
10 mm
Rear side
Содержание HF-W2000 50
Страница 37: ...C 12 This page is intentionally left blank ...
Страница 73: ...2 OPERATION 2 12 4 Click ACPI x64 based PC Microsoft ACPI Compliant System and PCI Express Root Complex ...
Страница 91: ...2 30 This page is intentionally left blank ...
Страница 147: ...This page is intentionally left blank ...
Страница 171: ...This page is intentionally left blank ...
Страница 183: ...This Page Intentionally Left Blank ...
Страница 211: ...This Page Intentionally Left Blank ...
Страница 250: ...10 SOFTWARE RAID1 10 7 Note In the RAS software the HDD and other auxiliary storage devices are generally called drives ...
Страница 286: ...10 SOFTWARE RAID1 10 43 Clicking Close redisplays the menu window ...