7. RESTORING THE FACTORY-SHIPPED CONDITION USING A RECOVERY DVD
7-11
7.3.2 Errors generated during the recovery process and corrective actions
When an error occurs during the recovery process, record the error message and the error code displayed in the
window, and take action as shown in the following table. If you take action accordingly but are still unable to
proceed with the recovery process, or if the no. 8 error message appears, contact our sales representative.
Table 7-1 Error messages generated during the recovery process
No.
Error message
Action
1
Retry time out. Please refer to the
INSTRUCTION MANUAL.
• Check the integrity of the system drive, such as by
performing read and write tests.
2
Image file is not found. Please
refer to the INSTRUCTION MANUAL.
• Retry the recovery process.
• Check the integrity of the recovery DVD, such as by
performing read tests.
• Verify that the DVD drive works properly, such as by
performing read tests.
3
Drive failed or not connected.
Please refer to the INSTRUCTION
MANUAL.
• Verify that the system drive is connected correctly.
• Check the integrity of the system drive, such as by
performing read and write tests.
4
Failed to access the drive. Please
refer to the INSTRUCTION MANUAL.
5
Failed to assign drive letter.
Please refer to the INSTRUCTION
MANUAL.
• Verify that no devices that are not required for the
recovery process are connected. If any such devices
are connected, disconnect them.
6
Failed to read from Product Recovery
DVD. Please refer to the INSTRUCTION
MANUAL.
• Verify that the DVD drive is connected correctly.
• Check the integrity of the recovery DVD, such as by
performing read tests.
• Verify that the DVD drive works properly, such as by
performing read tests.
7
Recovery failed. Please refer to the
INSTRUCTION MANUAL.
• Retry the recovery process.
8
Recovery invalid. Please refer to
the INSTRUCTION MANUAL.
• Contact one of our sales representatives.
9
Drive capacity is not enough. Please
refer to the INSTRUCTION MANUAL.
• Check the size of the system drive.
10
The capcity of drive is not equal.
• Install drives with equivalent capacities.
Содержание HF-W2000 50
Страница 37: ...C 12 This page is intentionally left blank ...
Страница 73: ...2 OPERATION 2 12 4 Click ACPI x64 based PC Microsoft ACPI Compliant System and PCI Express Root Complex ...
Страница 91: ...2 30 This page is intentionally left blank ...
Страница 147: ...This page is intentionally left blank ...
Страница 171: ...This page is intentionally left blank ...
Страница 183: ...This Page Intentionally Left Blank ...
Страница 211: ...This Page Intentionally Left Blank ...
Страница 250: ...10 SOFTWARE RAID1 10 7 Note In the RAS software the HDD and other auxiliary storage devices are generally called drives ...
Страница 286: ...10 SOFTWARE RAID1 10 43 Clicking Close redisplays the menu window ...