9. TROUBLESHOOTING
9-32
9.6.2 Display of hardware status codes
A hardware status code is displayed when an error occurs in the hardware during system operation.
When a hardware status code is displayed, the RAS status lamp in the status indication LEDs is lit in red.
Table 9-6 Hardware status codes and related causes and actions
Status
code
Cause
Action
12
The rotation of the system fan is abnormal.
Read the description in 9.2.2 (1) and take action
accordingly.
13
The rotation of the CPU fan is abnormal.
21
The temperature is abnormal.
Read the description in 9.2.2 (1) and take action
accordingly.
31
A failure is predicted for the drive in drive
bay 1.
We recommend that you back up the data and
replace the drive.
32
A failure is predicted for the drive in drive
bay 2.
41
#1
The drive in drive bay 1 is offline.
Replace the drive by referring to 10.4.2.
42
#1
The drive in drive bay 2 is offline.
4C
The RAID status is unknown (the RAS
software could not acquire the RAID
status).
Contact your system administrator or maintenance
personnel.
4D
#2
A media error occurred in the RAID.
See 2.8.2 Note about media errors in the HF-W2000
Model 58/55/50 RAS FEATURES MANUAL, and
take action accordingly.
#1: This code is also displayed during rebuilding.
#2: This code is not displayed when you are using the default settings. To display this code, see 2.8.2 Note about media
errors in the HF-W2000 Model 58/55/50 RAS FEATURES MANUAL.
NOTE
If a code other than one of preceding codes is displayed, contact the system administrator or maintenance
personnel.
Содержание HF-W2000 50
Страница 37: ...C 12 This page is intentionally left blank ...
Страница 73: ...2 OPERATION 2 12 4 Click ACPI x64 based PC Microsoft ACPI Compliant System and PCI Express Root Complex ...
Страница 91: ...2 30 This page is intentionally left blank ...
Страница 147: ...This page is intentionally left blank ...
Страница 171: ...This page is intentionally left blank ...
Страница 183: ...This Page Intentionally Left Blank ...
Страница 211: ...This Page Intentionally Left Blank ...
Страница 250: ...10 SOFTWARE RAID1 10 7 Note In the RAS software the HDD and other auxiliary storage devices are generally called drives ...
Страница 286: ...10 SOFTWARE RAID1 10 43 Clicking Close redisplays the menu window ...