10. SOFTWARE RAID1
10-18
10.4.3 Recovery from a power failure while the system is operating
NOTE
Use the following procedure only to disconnect the HDD in drive bay 2 in consideration of possible data
inconsistency between HDDs.
If a power failure occurs while the system is operating, the possibility of a data inconsistency between HDDs is
detected and the drive bay status in the Hardware status window appears as follows:
In this case, the HDD in drive bay 2 can be used continuously without being replaced.
Perform the following procedure to recover from this state:
1. Back up your data.
(See (2) Backing up files in 4. Hard Disk Drives (HDDs) and Solid State Drives (SSDs) in PRECAUTIONS.)
2. Execute the following command at the command prompt as an administrator:
C:\> raidctrl /REBUILD
3. The HDD status lamp blinks after a while and RAID1 rebuilding starts.
4. When the DRIVE status lamp turns off, rebuilding is complete. In the Hardware status window, verify that the
status of both HDDs is normal.
NOTE
Rebuilding is also enabled by using the software RAID utility. To rebuild RAID1 by using the software RAID
utility, see 10.6.4 Rebuilding feature.
Содержание HF-W2000 50
Страница 37: ...C 12 This page is intentionally left blank ...
Страница 73: ...2 OPERATION 2 12 4 Click ACPI x64 based PC Microsoft ACPI Compliant System and PCI Express Root Complex ...
Страница 91: ...2 30 This page is intentionally left blank ...
Страница 147: ...This page is intentionally left blank ...
Страница 171: ...This page is intentionally left blank ...
Страница 183: ...This Page Intentionally Left Blank ...
Страница 211: ...This Page Intentionally Left Blank ...
Страница 250: ...10 SOFTWARE RAID1 10 7 Note In the RAS software the HDD and other auxiliary storage devices are generally called drives ...