8. MAINTENANCE OPERATIONS
8-7
#3: The recommended settings are the settings in Advanced system settings in the Control Panel configured as
follows. These are the default settings when this equipment is shipped from the factory.
•
In Startup and Recovery, Complete memory dump is selected as the memory dump type.
•
In Startup and Recovery, Overwrite any existing file is selected.
•
In Performance, the Initial size and Maximum size settings for the virtual memory are the physical memory
size plus 300 MB.
When an incident occurs that triggers a memory dump or when the NMI switch is pressed, the window called the
blue screen appears, and the processing that triggers a memory dump is then started.
NOTE
•
The time required to collect a memory dump depends on the type of dump file collected, the configuration of
the installed drives, and the memory capacity. Note that when using the recommended setting for this equipment,
Complete memory dump, for the memory dump file type, the time required might be extremely long.
•
After the message
Beginning
dump
of
physical
memory
is displayed on the blue screen, the count on
the screen that shows the progress of the memory dump sometimes stops being updated. This occurs when the
collection of the memory dump fails due to an error in the file system or on a hard disk.
If this occurs, record the first five lines of the STOP message screen. Then press the NMI switch or turn the
power off and then back on to restart the equipment.
Содержание HF-W2000 50
Страница 37: ...C 12 This page is intentionally left blank ...
Страница 73: ...2 OPERATION 2 12 4 Click ACPI x64 based PC Microsoft ACPI Compliant System and PCI Express Root Complex ...
Страница 91: ...2 30 This page is intentionally left blank ...
Страница 147: ...This page is intentionally left blank ...
Страница 171: ...This page is intentionally left blank ...
Страница 183: ...This Page Intentionally Left Blank ...
Страница 211: ...This Page Intentionally Left Blank ...
Страница 250: ...10 SOFTWARE RAID1 10 7 Note In the RAS software the HDD and other auxiliary storage devices are generally called drives ...
Страница 286: ...10 SOFTWARE RAID1 10 43 Clicking Close redisplays the menu window ...