Run the
rxversion
command to check the device file names and OS versions for the active area and inactive
area (see the
bold underlined parts
).
$ sudo rxversion
<Inactive>(/dev/sda2)
CTRL-EDGEN-IMG
model-name
version-information
<Active><Running>(/dev/sda3)
CTRL-EDGEN-IMG
model-name
version-information
<BIOS>
version-information
<RAS MCU F/W>
<version information>
<TPM>
<version information>
$
6. Run the OS update command.
Run the
ecosupdate
command to update the OS in the inactive area and switch the system area that will be the
active area the next time the unit starts to the area containing the updated OS.
$ sudo ecosupdate /mnt/osupdate
7. Check the OS version and partition of the active area to be started next.
Run the
rxosenable
command with the
-p
(next startup area display) option specified. Then, confirm that the
partition to be started next has changed to the current inactive area, and the OS version of that inactive area is
updated (see the
bold underlined parts
).
$ sudo rxosenable -p
OS(
version-number
) is enabled. (
/dev/sda2
)
8. Unmount the external media from the unit.
After restoration finishes, unmount the connected external media from the unit.
$ sudo umount /mnt/osupdate
9. Remove the external media from the unit.
10. Reboot the unit.
$ sudo reboot
11. (No user operation required) Automatically log out from the unit.
Wait for the system to start.
12. Check the communication between the maintenance PC and the unit.
Run the
ping
command to confirm that the maintenance PC can communicate with the unit.
$ ping
IP-address-of-the-target-unit
13. Remotely log in to the unit from the maintenance PC.
Remotely log in to the unit.
Example user name:
edgeadm
login: edgeadm
Password: *******
14. Run the version display command to check the OS versions of the active area and inactive area.
Run the
showecmode
command to confirm that the OS operation mode is
Normal
mode
(see the
bold
underlined parts
).
$ sudo showecmode
Current :
Normal mode
Next :
Normal mode
$
Then, run the
rxversion
command to check the device file names and OS versions for the active area and
inactive area (see the
underlined parts
). In this example, confirm that the device file name of the active area
is
/dev/sda2
.
5. Configuring Software Environment
94
Содержание CE50-10
Страница 1: ...Hitachi Industrial Edge Computer CE50 10 Instruction Manual CC 65 0171 ...
Страница 10: ......
Страница 16: ...H 1 List of log capacities 176 H 2 Updating the encryption algorithm 176 I Communication Sheet 178 Contents vi ...
Страница 23: ...Figure 1 6 Attaching mounting brackets 4 1 Installing the CE50 10 7 ...
Страница 26: ......
Страница 38: ......
Страница 42: ...4 2 5 Connection diagram Figure 4 2 Connection diagram 4 External Contact Functions 26 ...
Страница 44: ......
Страница 52: ... gsettings set org gnome desktop background show desktop icons true 5 Configuring Software Environment 36 ...
Страница 87: ... sudo etc init d netfilter persistent save 5 Configuring Software Environment 71 ...
Страница 117: ...version information 13 Log out from the unit exit 5 Configuring Software Environment 101 ...
Страница 143: ...6 Managing User Accounts This chapter describes how to add and delete user accounts for the CE50 10 127 ...
Страница 148: ......
Страница 149: ...7 Maintaining the CE50 10 This chapter describes maintenance of the CE50 10 133 ...
Страница 157: ...8 Troubleshooting This chapter describes troubleshooting of the CE50 10 141 ...
Страница 159: ...Figure 8 2 Troubleshooting flow chart 8 1 1 Smoke or unusual odor WARNING 8 Troubleshooting 143 ...
Страница 162: ...8 1 14 Cannot turn off the power to the unit Please contact us 8 Troubleshooting 146 ...