3. Servicing
Electrical components
SMGB0097 rev.0 - 07/2015
81
3
Clamp
lever
4
Push the clamp lever to fix the plate in horizontal position
at the top.
3.4.5
Removal of the PCB’s
PCBa
7- segment display
Pressure switches (PSW)
PSW3, PSW4 PSW5 PSW6
Pressure switches (PSW)
PSW1, PSW2
Switches (SW)
SW1, SW2
DSW1, DSW2, DSW3
DSW4, DSW5, DSW6
Deep switches (PSW)
Rotary switches
(RSW1)
Plastic holder
Plastic holder
Plastic holder
a.
Remove the PCB by press
-
ing the expanded part of the 4
plastic holders, using long-nose
pliers, as shown in the picture
below.
b.
Pull the PCB out from the PCB
plate.