Error code list
© 2009 Hirschmann Automation and Control GmbH · Branch Office Ettlingen · eMail: [email protected] · www.hirschmann.com
42
24 183 19 1012e (Generic) / 2009-02-26 / Rev. 01 / rk.
Error Code
Error
Cause
Elimination
E32
Error in the power
supply
•
+UB System not present at the
system start
•
+UB System not present at the
system finish
•
Contact problems at +UB
switch off/on
•
+UB System and +UB Power
must be wired separately: +UB
System connected direct with
the crane battery. +UB Power
for switch on/off
•
+UB switch off/on again
E37
Error in the logical
program flow
•
System program file is
defective
•
Flash-EPROM
defective
•
Upload valid system software
•
Replace central unit
E38
System program and
crane data file do not
match.
•
The system program in the LMI
does not match to the
programming in the crane data
file
•
Upload valid system program
file or the valid crane data file
E39
System program and
load chart file do not
match
•
The system program in the LMI
and the programming in the
load chart file do not match.
•
Upload valid system program
file or the valid load chart file
E43
Error in the write/read
memory, (RAM)
•
Write/read memory (RAM) or
central unit defective.
•
Replace central unit
E47
Error in the monitored
write/ read memory.
The CRC verification of
the monitored write/read
memory provides an
incoherent result
•
The CRC sign of the monitored
write/read memory is wrong
•
The buffer battery is decharged
(< 2V at 1kOhm).
•
Central unit defective.
•
Restart the LMI
•
Replace buffer battery on the
central unit.
•
Replace central unit
E51
Error in the crane data
file
•
No valid data in the crane data
file.
•
Flash-EPROM
defective
•
Upload valid crane data file
•
Replace central unit
E52
Error in load chart file.
•
No valid data in the load chart
file
•
Flash-EPROM
defective
•
Upload valid load chart file
•
Replace central unit
E53
Wrong setup of min.
analog inputs length1,
angle1, pressure1
•
Analog input not supported
•
Setup correct Flag in in DGA
6.i.2
E56
Error in crane data file.
•
No valid data in the crane data
file during calibration.
•
Flash-EPROM
defective
•
Restore or upload valid crane
data file
•
Replace central unit
E57
Error in serial crane
data file.
•
Calibration data file does not
contain valid data.
•
Flash-EPROM
defective
•
Upload calibration data file by
changing data (OM, limits) and
save
•
Replace central unit
•
CAN Bus cable between the
central unit and the sensor unit
defective or not connected.
•
Check the connection between
the central unit and the sensor
units
•
Can bus port in the central unit
defective
•
Replace the central unit
E61
Error in the CAN bus
data transfer for all CAN
units
•
Short circuit in a CAN Bus
cable
•
Replace Can Bus cable