Error code list
© 2009 Hirschmann Automation and Control GmbH · Branch Office Ettlingen · eMail: [email protected] · www.hirschmann.com
40
24 183 19 1012e (Generic) / 2009-02-26 / Rev. 01 / rk.
Error Code
Error
Cause
Elimination
•
Pressure
transducer
is
defective.
•
PDB variable for analog value
not supported
•
Replace pressure transducer
•
Setup of correct PDB variable
for analog value in DGA6.i.3
E12
Fallen below the lower
limit value in the
measuring channel
"pressure piston side"
•
Electronic component in the
measuring channel is defective.
•
Replace sensor unit
E13
Fallen below lower limit
value in the measuring
channel "pressure rod
side"
•
refer to E12
•
refer
to
E12
E14
Fallen below lower limit
value in measuring
channel "force"
•
Force transducer defective
•
Electronic component in the
measuring channel is defective.
•
Replace force transducer
•
Replace sensor unit
•
Angle
potentiometer
defective
•
PDB variable for analog value
not supported
•
Replace angle sensor
•
Setup of correct PDB variable
for analog value in DGA6.i.3
E15
Fallen below lower limit
value in measuring
channel "angle main
boom"
•
Electronic component in the
measuring channel defective.
•
Replace sensor unit
•
Angle
potentiometer
defective
•
Replace angle sensor
E16
Fallen below lower limit
value in measuring
channel "angle 2"
•
Electronic component in the
measuring channel defective.
•
Replace sensor unit
•
Length potentiometer defective
•
Replace
length
sensor.
E17
Fallen below lower limit
value "length telescope I
(+II)"
•
Electronic component in the
measuring channel defective
•
Replace sensor unit
E18
Front outrigger
overloaded
•
Front
outrigger
overloaded
•
•
Cable between the central unit
and the slewing angle sensor
defective or loose. Water inside
the plug of the angle sensor
•
1-cannel slew sensor min. value
DGA 11.5.7 <> 0
•
Check cable as well as plugs,
replace, if need be.
•
move to allowed slew range
•
Slewing angle potentiometer is
defective
•
Replace slewing angle sensor
E1A
Fallen below lower limit
value in measuring
channel "slewing angle
1".
slew below allowed
range
•
Electronic component in the
measuring channel defective
•
Replace sensor unit
E1B
Fallen below lower limit
value in measuring
channel "slewing angle
2"
•
refer to E1A
•
refer
to
E1A
E1C
Fallen below lower limit
•
Angle
potentiometer
defective
•
Replace angle sensor