background image

                                                      

 

 

 

 

 

USER MANUAL  

 

HTP1010 KNX­IO 

 

 

KNX Multi Function Touch Panels with Intercom

 

 

 

 
 

 Copyright © 2015 EMT Kontrol Elektronik. All rights reserved 

EMT Controls and the EMT logo are registered trademarks of EMT Kontrol Elektronik Ltd.  

All other trademarks are the property of their respective owners. 

 

Summary of Contents for HTP1010 KNX-IO

Page 1: ...ction Touch Panels with Intercom Copyright 2015 EMT Kontrol Elektronik All rights reserved EMT Controls and the EMT logo are registered trademarks of EMT Kontrol Elektronik Ltd All other trademarks are the property of their respective owners ...

Page 2: ...P Connection All three devices 2 2 Intercom Configuration HTP1010 KNX IO 2 3 KNX Controller and EMT Builder PC Software All three devices 2 4 Mailbox Configuration HTP1010 KNX IO 2 5 Concierge Function HTP1010 KNX IO 3 KNX Functions and Device Inputs Outputs HTP1010 KNX IO 3 1 Inputs of HTP1010 KNX IO 3 1 1 ON OFF Button and Push Button Functions 3 1 2 Toggle Button Function 3 1 3 Scene Function 3...

Page 3: ...touch panel solutions for the entire control and intercom functionality for building automation systems Device has many solutions which can increase the comfort like Intercom VoIP telephony Home Automation Control Messaging and Concierge services HTP1010 KNX IO devices also allow you to monitor your home while you are away and control your building automation devices using your mobile devices Thre...

Page 4: ... HTP1010 KNX IO 4 Inputs Digital Analog Configurable Digital Inputs Range 0 5 VDC Max Analog Inputs Range 0 10 V Hardware Dependent Temperature range 0 50 ºC Case material Aluminium and Glass Dimensions W x H x D Touch Panel Floating 283 x 185 x 30 mm Back Box In wall 278 x 163 x 40 mm Height Touch Panel Floating 1500 gr Back Box In wall 550 gr ...

Page 5: ...1 3 Wiring Diagrams HTP1010 KNX IO devices can be assembled in different configurations with different equipments Below is a typical diagram for a HTP1010 KNX IO based system ...

Page 6: ...PoE technology 802 3af PoE 48 V 380 mA DC Thus only ethernet cable is enough for both power supply and Internet communication of device HTP1010 KNX IO needs internet connection to be able to perform its communication tasks Below is a figure representing the power and ethernet connection ...

Page 7: ...d to KNX Twisted Pair medium Standard KNX Twisted Pair connector is used for this purpose WARNING Assembly installation and commissioning of system must only be carried out by a qualified electrician WARNING Do not cut wires when HTP1010 KNX IO is powered It can destroy communication circuits of device ...

Page 8: ... IO HTP1010 KNX IOE can be integrated to the intercom system of a building Intercom service is provided via VoIP telephony and device can be configured and registered to a SIP server over IP network Intercom function of device allows users to answer calls from the building entrance or make calls to other devices apartments buildings connected to the SIP server Intercom function does not only provi...

Page 9: ...By tapping the Call button a keypad pops up and user can dial the number of destination ...

Page 10: ......

Page 11: ...elled and imported as a project to HTP1010 KNX IO devices When prepared as a project your building automation system can be controlled via touch panel over the KNX twisted pair bus HTP1010 KNX IO devices does not require any external devices or gateways to connect with KNX Twisted Pair medium Standard KNX TP connectors are included on the device With the graphical user interface of KNX Controller ...

Page 12: ... when you are not home 1 7 Mailbox Function HTP1010 KNX IO Using the Mailbox function of HTP1010 KNX IO different devices connected to server can send messages to each other This function can be used by residents to communicate easily and also allows notifications and announcements to be delivered to a device or group of devices Each device can both send and receive messages device has a user frie...

Page 13: ...By clicking compose button user will see the screen below ...

Page 14: ......

Page 15: ...concierge services to user via HTTP connection By connecting to a web server device receives the concierge services from server and display additional options on concierge menu like finding a florist or calling a taxi etc Concierge function screen looks like this ...

Page 16: ...assigning a username password and registering the device to server devices can be used as a user panel for any intercom application 2 3 KNX Controller and EMT Builder PC Software All three devices HTP1010 KNX IO HTP1010 KNX IO can be used for controlling any KNX device on a building automation installation By using the general touch input easy to use user controls like buttons sliders and input bo...

Page 17: ...s into the selected room We can add rooms and devices without any limit Above the columns there are buttons for adding removing moving up and moving down rooms or devices Also there are text boxes for editing names of these items above the buttons Once we select a device in the project we can change device parameters from the Device options menu ...

Page 18: ...ration like mailbox information and username password parameters These parameters are available on settings menu of HTP1010 KNX IO 2 5 Concierge Function HTP1010 KNX IO Concierge function of HTP1010 KNX IO is a screen which displays and allows user to interact with a web page This web page can be on any server from the IP network which device is connected Concierge options are available on setting...

Page 19: ...ion objects via the ETS software Below is the table of functions and related communication objects for each function of inputs 3 1 1 ON OFF Button and Push Button Functions ON OFF buttons can perform only one operation According to its ETS configuration an ON OFF button can transmit either ON or OFF value to the KNX bus If any input is configured as a push button it will have the Push Button objec...

Page 20: ...ible via ETS These objects are ON OFF object and Output Status object Each time the button is pressed the invert of the previous state of the output is sent to the bus via the ON OFF object of the touch button Feedback about current state of the output device is obtained via the Output Status object of the input Figure Block Diagram Representation of Toggle Function ...

Page 21: ... one communication object available on ETS which is the Analog Value object This object is a read only object which continuously updates its value by the periodic measurements performed by HTP1010 KNX IO This measurements can be used as input for control scenarios as they are available as generic inputs An example for usage of this configuration would be to turn on a light when the illumination le...

Page 22: ...nking above objects with appropriate input devices these relays can be programmed to achieve many different switching tasks and scenarios Digital outputs can be used as generic digital switches by three configuration If timer and scene functions are disabled they will simply operate as a switch and close contacts when they receive messages from the bus If the timer of a digital output is enabled i...

Page 23: ...le to EMT Controls occurs during the warranty period above This warranty does not cover defects caused by the delivered product reaching the end of its service life and replacement of parts that require replacement or that have a limited service life This warranty does not cover failures that result from any of the following causes 1 Improper handling abuse or use in unsuitable conditions or in en...

Page 24: ... provided for the purpose of the customer purchasing the appropriate product for the intended application The use therefore does not guarantee that there are no infringements of intellectual property rights or other proprietary rights of EMT or third parties nor does it construe a license 4 EMT Controls shall not be responsible for any damage arising from infringements of intellectual property rig...

Page 25: ... Other systems that require a similar high degree of safety 4 Never use the product for an application involving serious risk to life or property without first ensuring that the system is designed to secure the required level of safety with risk warnings and redundancy and that the EMT product is properly rated and installed 5 The circuit examples and other application examples described in produc...

Page 26: ...END OF DOCUMENT ...