Error code list
© 2009 Hirschmann Automation and Control GmbH · Branch Office Ettlingen · eMail: [email protected] · www.hirschmann.com
43
24 183 19 1012e (Generic) / 2009-02-26 / Rev. 01 / rk.
Error Code
Error
Cause
Elimination
•
Cable between the central unit
and the sensor unit defective.
•
Check the cable to the sensor
unit
•
Can bus port in the central unit
defective
•
Replace the central unit
•
Can bus port in the sensor unit
is defective
•
Replace the sensor unit
E62
Error in the can bus data
transfer of the pressure
transducer sensor unit
•
Sensor unit is defective
•
Replace the sensor unit
E63
Error in the can bus
pressure transducer
sensor unit
•
The analog values of the
sensor unit are invalid
•
Replace the sensor unit
E64
Error in the can bus data
transfer of the
length/angle sensor unit
•
See
E62
•
See
E62
E65
Error in the can bus
length/angle sensor unit
•
See
E63
•
See
E63
E66
Error in the data of the
digital I/O MENTOR
•
PDB
variable
invalid
•
Change
system
software
•
Change
MENTOR
E67
Error in the can bus data
transfer of the digital I/O
external module
•
PDB
variable
invalid
•
Connect digital I/O external
CAN module
E68
Error in the can bus data
transfer of the force
sensor unit
•
See
E62
•
See
E62
E69
Error in the can bus
force sensor unit
•
See
E63
•
See
E63
E84
Wrong rigging condition.
•
The selected rigging condition
is not contained in the crane
data file.
•
Select another rigging condition
•
Check the programming in the
crane data file.
E85
Error in the radius
determination
•
The computed radius is too
small (negative deflection)
•
Check the programming in the
crane data file.
E89
Operating mode
switchover with load.
•
The operating mode on the
console has been switched over
with the boom loaded.
•
Select operating mode without
load on the boom
E98
LMI watchdog activated
•
LMI processing time limit
exceeded
•
Reset
system
•
Connect PC terminal and watch
error messages
EAB
Short circuit in the A2B
switch circuit
(not with radio A2B)
•
Short circuit in the A2B switch
•
Short circuit in the cable to the
A2B switch
•
Replace A2B switch
•
Replace cable to the A2B
switch
EAC
A2B switch circuit
disconnected
(not with radio A2B)
•
Disconnected cable in the A2B
switch
•
Disconnected cable to the A2B
switch
•
Connect or replace cable in the
A2B switch
•
Connect or replace cable to the
A2B switch