background image

 

USER GUIDE 

 
 

 

www.kontron.com 

 

// 1 

 

 

FlatView HYG  

Doc. User Guide Rev. 1.0        

Doc. ID: 1067-7845 

 

Summary of Contents for kontron FlatView HYG

Page 1: ... USER GUIDE www kontron com 1 FlatView HYG Doc User Guide Rev 1 0 Doc ID 1067 7845 ...

Page 2: ...FlatView HYG User Guide Rev 1 0 www kontron com 2 This page has been intentionally left blank ...

Page 3: ...be suitable for the specified use without further testing or modification Kontron expressly informs the user that this user guide only contains a general description of processes and instructions which may not be applicable in every individual case In cases of doubt please contact Kontron This user guide is protected by copyright All rights are reserved by Kontron No part of this document may be r...

Page 4: ...ely at your risk To minimize the risks associated with your products and applications you should provide adequate design and operating safeguards You are solely responsible for compliance with all legal regulatory safety and security related requirements concerning your products You are responsible to ensure that your systems and any Kontron hardware or software components incorporated in your sys...

Page 5: ...upport Find Kontron contacts by visiting http www kontron com support Customer Service As a trusted technology innovator and global solutions provider Kontron extends its embedded market strengths into a services portfolio allowing companies to break the barriers of traditional product lifecycles Proven product expertise coupled with collaborative and highly experienced support enables Kontron to ...

Page 6: ...escribed by the law may endanger your life health and or result in damage to your material ESD Sensitive Device This symbol and title inform that the electronic boards and their components are sensitive to static electricity Care must therefore be taken during all handling operations and inspections of this product in order to ensure product integrity at all times HOT Surface Do NOT touch Allow to...

Page 7: ...a central grounding point shall remain connected The earth ground cable shall be the last cable to be disconnected or the first cable to be connected when performing installation or removal procedures on this product Special Handling and Unpacking Instruction ESD Sensitive Device Electronic boards and their components are sensitive to static electricity Therefore care must be taken during all hand...

Page 8: ...product then re pack it in the same manner as it was delivered Special care is necessary when handling or unpacking the product See Special Handling and Unpacking Instruction Quality and Environmental Management Kontron aims to deliver reliable high end products designed and built for quality and aims to complying with environmental laws regulations and other environmentally oriented requirements ...

Page 9: ...Product Specification 19 6 1 Block Diagrams 19 6 2 Technical Specification 20 6 3 Mechanical Specification 20 6 4 Environmental Specification 21 6 5 Certification 21 6 6 Power Specification 22 7 Order Information 23 8 Mechanical Diagrams 24 8 1 21 5 Support Arm 24 8 2 21 5 VESA M12 25 9 Connectors 26 9 1 FlatView HYG Support Arm Connectors 26 9 1 1 Power Connector 26 9 1 2 Display Port 26 9 1 3 US...

Page 10: ...able 8 Electrical Specification 22 Table 9 Power Connector Cable with Wire End Ferrules 26 Table 10 Display Port Connector Pin Assignment 26 Table 11 USB 2 0 Type A Connector Pin Assignment 26 Table 12 M12 A coded male Power Connector Pin Assignment 27 Table 13 Display Port Connector Pin Assignment 27 Table 14 USB 2 0 Type B Connector Pin Assignment 28 Table 15 List of Acronyms 34 List of Figures ...

Page 11: ... guidelines With a completely sealed stainless steel housing and IP69K protection the FlatView HYG is highly resistant to detergents and prepared for easy cleaning and wash down The 21 5 industrial monitor offers PCAP touch or protection glass with anti glare surface for best readability Mounting options with support arm or VESA and operation in landscape or portrait mode guarantee utmost flexibil...

Page 12: ...Power Source PS2 of UL IEC 62368 1 Only products or parts that meet the requirements for Power Source PS1 of UL IEC 62368 1 may be connected to the product s available interfaces I O Before opening the product make sure that the product is disconnected from the mains Switching off the product by its power button does not disconnect it from the mains Complete disconnection is only possible if the p...

Page 13: ...er and input signals before inserting and removing connectors or connecting test equipment 2 2 Grounding Methods Proper grounding methods are necessary to avoid damage to the product Always take the following general precautions 1 Ensure the product is grounded before powering on the product 2 Connect the product only to an applied ground that meets all applicable local national and international ...

Page 14: ...inal order 4 Keep the associated paperwork It contains important information for handling the product 5 Check the product for visible shipping damage If you notice any shipping damage or inconsistencies between the contents and the original order contact your dealer 3 3 Scope of Delivery Check that your delivery is complete If you discover damaged or missing items contact your dealer Table 1 Scope...

Page 15: ...mm polyester matt silver Figure 2 Type Label Example 1 Model name FlatView HYG 2 Part number and barcode 3 Serial number and barcode 4 Certifications 5 Optional certification 6 Product revision and production date 7 Internal use 8 Electrical specification Certifications such as UL or FCC may be requested optionally 2 4 8 3 6 7 1 5 ...

Page 16: ...066 7600 Power Cable M12 IP67 protected length 2 m 1 1067 9450 Power Cable M12 IP67 protected length5 m 3 EN05 100009 01 Connector clamps 1 1066 7603 Dust cap HDMI connector IP67 protected 1 1066 7603 Dust cap USB connector IP67 protected 1 1066 7665 HDMI cable one side IP67 protected Length 2 m 1067 9452 HDMI cable one side IP67 protected Length 5 m 1 1067 0468 USB 2 0 Type B IP67 protected to Ty...

Page 17: ...ron com 17 5 Product Description Figure 3 Front View FlatView HYG 1 TFT Display with PCAP touch Figure 4 Rear View FlatView HYG Support Arm 1 Support arm bracket with 48 mm tube Rittal 6664 500 2 2x Support arm bracket fastening screws 1 1 2 ...

Page 18: ...FlatView HYG User Guide Rev 1 0 www kontron com 18 Figure 5 Rear View FlatView HYG VESA 1 1x HDMI 2 1x USB 3 VESA 100 pattern 4 Protective Vent 5 Power Connector 6 Stud 1 4 5 2 3 6 ...

Page 19: ...el shifter DC DC Backlight Arm mounted IP69 default optional Display LVDS Coupling Support arm Touch USB Display Port Vin 12 30V Figure 7 Block Diagram FlatView HYG VESA Display Controller LED Converter PWM level shifter DC DC Backlight Vin 12 30V VESA mounted IP67 default optional Display LVDS HDMI Touch USB IP67 Cable entry IP67 Cable entry IP67 Cable entry Pressure compensation ...

Page 20: ...zes and resolutions 6 3 Mechanical Specification Table 5 Mechanical specification VESA Support Arm Dimensions WxHxD mm 1 without connector mounting bracket 542 x 366 x 74 mm 21 3 x 14 4 x 2 9 542 x 366 x 126 mm 21 3 x 14 4 x 4 9 Mounting VESA 100 pattern with 4x M4 screw Support arm bracket with 48 mm tube compatible with Rittal 6664 5000 48 mm Viewing Area 476 63 x 268 11 mm 18 7 x 10 5 Weight 10...

Page 21: ...ay lead to higher temperatures inside the product and cause permanent damage Direct exposure accelerates long term aging For intend use in an outdoor environment or a sunlit environment contact your Kontron representative 6 5 Certification The FlatView HYG complies with the following standards Table 7 Certification CE Marking CE cULus with CB report pending Safety EN 62368 1 pending EMC EN55032 Cl...

Page 22: ...t Current I max 3 A Power max 65 W Only connect the product to an external power supply providing the voltage type AC or DC and the input power max current specified on the Kontron Product Label and meeting the requirements of the Limited Power Source LPS and Power Source PS2 of UL IEC 62368 1 Ne connectez le produit qu à une alimentation externe fournissant le type de tension AC ou DC et la puiss...

Page 23: ...EN00 yyyyyy xx 1 Product family Z FlatView 2 Display size 8 21 5 3 Touch Technology 3 Protection safety glass 5 Touch PCAP C PMMA D Touch PCAP PMMA 4 Mounting Variant 8 HYG Monitor VESA 9 HYG Monitor Support Arm 5 Options Used on demand 6 Internal Code Revision 1 2 5 6 3 4 ...

Page 24: ...FlatView HYG User Guide Rev 1 0 www kontron com 24 8 Mechanical Diagrams 8 1 21 5 Support Arm ...

Page 25: ...FlatView HYG User Guide Rev 1 0 www kontron com 25 8 2 21 5 VESA M12 ...

Page 26: ... with Wire End Ferrules Wire Color Signal Name Black GND White VIN 24 VDC Green Functional Earth FE 9 1 2 Display Port The display port cable terminates with a 20 pin DP connector Table 10 Display Port Connector Pin Assignment Display Port Connector Pin Signal Name Pin Signal Name 1 TX0 2 GND 3 TX0 4 TX1 5 GND 6 TX1 7 TX2 8 GND 9 TX2 10 TX3 11 GND 12 TX3 13 GND 14 GND 15 AUX 16 GND 17 AUX 18 Hot P...

Page 27: ...DC 3 GND 4 GND 5 Functional Earth FE To ensure IP67 protection screw the mating connector firmly to the M12 A coded male power connector 9 2 2 HDMI IP67 Protected Table 13 Display Port Connector Pin Assignment HDMI Connector IP67 Protected Pin Signal Name Pin Signal Name 1 TMDS Data2 11 Ground 2 Ground 12 TMDS Clock 3 TMDS Data2 13 Reserved 4 TMDS Data1 14 Reserved 5 Ground 15 DDC_CLK 6 TMDS Data1...

Page 28: ... www kontron com 28 9 2 1 USB Touch IP67 Protected This connector provides a USB 2 0 upstream connection Table 14 USB 2 0 Type B Connector Pin Assignment USB Touch Connector IP67 Protected Pin Signal Name 1 5V 2 Data 3 Data 4 Ground ...

Page 29: ...Mounting The FlatView HYG s support arm bracket is compatible with the Rittal 6664 5000 48 mm tube When mounting only use a support arm fixture compatible with the Rittal 6664 5000 48 mm tube To mount slide the support arm fixture into the support arm bracket and fasten using the two screws located on the support arm bracket see Figure 4 pos 2 Only mount using a corresponding support arm fixtures ...

Page 30: ...always be the power cable Observe and comply with the product s electrical specification on the Type Label 10 3 1 Starting up FlatView HYG Support Arm To connect the FlatView HYG Support Arm to an external DC power supply perform the following 1 Switch off the external DC power supply via a disconnecting device fuse circuit breaker to ensure that no power flows during the connection procedure 2 Id...

Page 31: ...tact Kontron Support or return the product for repair If the product protection label is broken the warranty is invalidated 11 1 Cleaning With a completely sealed stainless steel housing and IP67 IP69K protection the FlatView HYG is highly resistant to most detergents and prepared for easy cleaning and wash down The FlatView HYG s smooth flat joint less surfaces are ideal for the easy removal of d...

Page 32: ...m does not work or you do not get a response within 48 hours follow up with support kontron com Make sure you have the following product identification information on hand when you call Product name Product Model number Serial number SN of the unit The serial number can be found on the product s type label Be ready to explain the nature of your problem to the service technician 12 1 Warranty Due t...

Page 33: ...pport rma information 2 Download the RMA Request sheet for Kontron Europe GmbH Ismaning and fill out the form Take care to include a short detailed description of the observed problem or failure and to include the product identification Information Name of product Product number and Serial number If a delivery includes more than one product fill out the above information in the RMA Request form fo...

Page 34: ...ent Platform Management Interface LED Light Emitting Diode LPS Limited Power Source PCAP Protective capacitive touch PCIe PCI Express PMMA Poly methyl methacrylate PS Power source RMA Return Material Authorization SELV Safety Extra Low Voltage TPM Trusted Platform Module UEFI Unified Extensible Firmware Interface USB Universal Serial Bus VESA Video Electronics Standards Association WEEE Waste Elec...

Page 35: ...s and tailor made solutions based on highly reliable state of the art embedded technologies Kontron provides secure and innovative applications for a variety of industries As a result customers benefit from accelerated time to market reduced total cost of ownership product longevity and the best fully integrated applications overall For more information please visit http www kontron com Global Hea...

Reviews: