120
SW1001, SW1002 Input Specifications/Output Specifications/Measurement Specifications
9.2
SW1001, SW1002 Input Specifications/Output
Specifications/Measurement Specifications
Basic specifications
Number of slots
3 slots (SW1001), 12 slots (SW1002)
Analog bus
Number of systems
2-wire 4-system (automatic selection based on the module
and connection method)
Terminal
BNC receptacle × 4 (4-terminal pair)
Banana terminal receptacle × 4 (4-wire)
Banana terminal receptacle × 2 (2-wire)
Maximum input voltage
60 V DC, 30 V AC rms, 42.4 V peak
Maximum rated voltage
to earth
60 V DC
(Anticipated transient overvoltage: 60 V)
Compatible module
Model SW9001 Multiplexer Module
Model SW9002 Multiplexer Module
Number of instruments
to be connected
Maximum 2
One 2-wire + one 4-wire or
one 2-wire + one 4-terminal pair
HIOKI SW1001A961-04
Содержание SW9001
Страница 2: ...HIOKI SW1001A961 04...
Страница 42: ...38 Channel Delay Function HIOKI SW1001A961 04...
Страница 48: ...44 Scan Measurement Example HIOKI SW1001A961 04...
Страница 50: ...46 Checking the Device Status HIOKI SW1001A961 04...
Страница 52: ...48 Initialization Settings HIOKI SW1001A961 04...
Страница 118: ...114 Sample Programs 3 Select FILE Save All HIOKI SW1001A961 04...
Страница 160: ...156 Outline Drawings 12 4 Outline Drawings SW1001 Unit mm Tolerance 0 2 HIOKI SW1001A961 04...
Страница 161: ...157 Outline Drawings SW1002 Unit mm Tolerance 0 2 12 Appendix HIOKI SW1001A961 04...
Страница 162: ...158 Outline Drawings HIOKI SW1001A961 04...
Страница 164: ...160 HIOKI SW1001A961 04...
Страница 167: ...HIOKI SW1001A961 04...
Страница 168: ...HIOKI SW1001A961 04...
Страница 169: ...HIOKI SW1001A961 04...