![Hioki 3197 Скачать руководство пользователя страница 178](http://html.mh-extra.com/html/hioki/3197/3197_instruction-manual_2137178178.webp)
Appendix 1 Interval and Recording Time Settings
A
2
15min
31days
6hours
2day
9
18days 8hours
7days
19hours
30min
12hour
9
4days 14hours
3day
9
27days 12hours
1day
9
4day
9
30min
62days
12hours
4day
9
36days 16hours
15days
15hours
1day
9
9days 4hours
5day
9
45days 20hours
2day
9
6day
9
55days
7day
9
60min 125days
7day
9
64days 4hours
31days
6hours
2day
9
18days 8hours
8day
9
73days 8hours
3day
9
27days 12hours
9day
9
82days 12hours
4day
9
10day
9
91days 16hours
11day
9
100days 20hours
12day
9
110days
13day
9
119days 4hours
14day
9
Interval setting: [Auto]
Re
co
rd
in
g
Int
e
rv
al
*1
When memory partitioning is set [OFF]
When memory partitioning is set [ON]
Lo
nge
s
t
Re
co
rd
in
g
Tim
e
*2
Tim
e
P
lo
t
d
iv
*3 (
/d
iv)
N
u
m
ber
o
f
d
ivisi
o
n
s *4
(d
iv)
Di
sp
la
y
pe
ri
od
*5
Lo
nge
s
t
Re
co
rd
in
g
Tim
e
*2
Tim
e
P
lo
t
d
iv
*3 (
/d
iv)
N
u
m
ber
o
f
d
ivisi
o
n
s *4
(d
iv)
Di
sp
la
y
pe
ri
od
*5
Recording Start Time: August 26, 2005, 13:09:11 (Recording Interval: 1 sec)
Recording
Starts
Recording Start Time: 14:00:00 (Measurement data is deleted 50 min 48 sec from the start time)
After 50 minutes, (Recording Interval changes from 1 sec
→
2 sec)
After 1 hour 40 min, (Recording Interval changes from 2 sec
→
10 sec)
(Measurement Data Compaction)
(Measurement Data Compaction)
(Measurement Data Compaction)
Recording Start Time: 13:09:12 (Measurement data is deleted 1 sec from the start time)
Recording Start Time: 13:09:20 (Measurement data is deleted 9 sec from the start time)
After 62 days 12 hours (Recording Interval changes from 30 min
→
60 min)
Содержание 3197
Страница 1: ...3197 POWER QUALITY ANALYZER May 2012 Revised edition 7 3197A981 07 12 05H Instruction Manual ...
Страница 2: ......
Страница 8: ...Contents vi ...
Страница 30: ...1 3 Measurement Flowchart 22 ...
Страница 44: ...2 5 Internal Operating Status and Memory Usage 36 ...
Страница 86: ...4 6 Initializing the Instrument System Reset 78 ...
Страница 117: ...6 3 Viewing Anomalous Phenomena EVENT screen 109 6 Viewing the INRUSH Screen DETAILS WAVEFORM INRUSH ...
Страница 134: ...6 4 Viewing Recorded Data REVIEW State 126 ...
Страница 139: ...7 2 Installing JRE 131 7 5 When the installation process has completed successfully click Finish Click ...
Страница 176: ...9 4 Disposing of the Instrument 168 ...
Страница 199: ......
Страница 200: ...3197 POWER QUALITY ANALYZER May 2012 Revised edition 7 3197A981 07 12 05H Instruction Manual ...