Electrical/Hydraulic Trouble Shooting 23
ELECTRICAL/HYDRAULIC TROUBLE SHOOTING
WARNING: Stand clear of the moldboard
and other moving parts while perform-
ing these tests.
Tools Required: Test Light or Voltage - Ohmmeter.
The following steps can be used to readily deter-
mine if your problem is electrical or hydraulic.
1. Checking for hydraulic pump operation.
-
Using a test light or Volt-Ohmeter (VOM), place
the negative test lead at point 2 in the photo-
graph and place the positive test lead at point
1.
-
With the truck ignition switch turned on, the cab
control turned on and the UP control activated,
the test light should glow or the VOM should
read 9 VDC or more.
-
If voltage is present between points 1 & 2 when
UP is activated, but the pump does not turn on,
the problem is with the hydraulic unit.
1
2
3
PHOTO NO. 1000320A
2. Checking down (float) operation.
-
Using a test light or Volt-Ohmeter (VOM), place
the negative test lead at point 2 in the photo-
graph and place the positive test lead at point 3.
-
With the truck ignition switch turned on, the
cab control turned on and the DOWN control
activated, the test light should glow or the VOM
should read 10 VDC or more.
-
If voltage is present between points 2 & 3
when DOWN is activated, but the moldboard
does not drop, the problem is with the hydrau-
lic unit.
3. Checking Angling functions.
4
5
PHOTO NO. 1000324A
-
Using a test light or Volt-Ohmeter (VOM), place
the negative test lead at point 2 in the photo-
graph and place the positive test lead at point
4 or 5.
-
With the truck ignition switch turned on, the cab
control turned on , activate the LEFT control.
The test light should glow or the VOM should
read 10 VDC or more.
-
If voltage is present between points 2 & 4 or
between 2 & 5 when LEFT is activated, but the
angling cylinders do not extend or retract, the
problem is with the hydraulic unit.
-
Using a test light or Volt-Ohmeter (VOM), place
the negative test leads at point 2 in the photo-
graph and place the positive test lead at point 4
or 5 (The one not tested in the steps above).
-
Activate the Right control, voltage should again
be present between point 2 and 4 or between
points 2 & 5. If voltage is present but the cylin-
ders do not extend or react, the problem is with
the hydraulic unit.