Plow Will Not Stay Up 9
PLOW WILL NOT STAY UP.
ALL OTHER FUNCTIONS ARE NORMAL.
REMOVE, INSPECT AND CLEAN CHECK VALVE.
SEE PAGE 13.
DOES PLOW STAY UP?
Remove, inspect and clean NC
Release Valve.
See page 15.
Does plow stay up?
Momentarily move joystick to the Up po-
sition to ensure that the float mode is
Off.
Verify that there is no voltage at the NC Re-
lease Valve, using a voltmeter or test light.
Is voltage present?
Yes
No
Yes
No
End
Refer to electrical troubleshooting.
Does Plow Stay Up?
Yes
No
End
Yes
No
Call Hiniker Service
End
PLOW WILL NOT STAY UP
Perform all initial inspections and checks listed on page 2 before beginning test procedure.
WARNING: Never disconnect any hydraulic line or fitting with the unit in the raised posi
-
tion. Always lower the unit and relieve pressure before removing any lines or caps. Allow
the system to cool down before draining oil or handling system components. Serious
burns can result from contact with hot oil.
Call Hiniker Service
Содержание DB-7929-1
Страница 2: ......
Страница 4: ...Power Unit Hydraulic POWER UNIT STRAIGHT AND SCOOP PLOW DWG NO 6586 ...
Страница 5: ...Power Unit Hydraulic Circuit Diagram POWER UNIT HYDRAULIC CIRCUIT DIAGRAM DWG NO 4180A ...
Страница 39: ...Notes 33 NOTES ...