Firmware recovery via HTTP
86/95
Note:
If the default IP address
0.0.0.0
is displayed, the gateway has not
yet received an IP address from a DHCP server. Make sure that the
gateway is connected to a subnet with an active DHCP server.
Then restart the gateway by briefly disconnecting the voltage supply
while the Ethernet cable remains plugged-in. Wait a few seconds
after reconnecting the voltage supply, then click the
Search
Devices
button in the
Ethernet Device Configuration
Tool again.
3. Open web page for firmware download.
Ø
Start the web browser on your configuration PC.
Ø
In the address bar of your browser, enter the IP address of the gateway:
http://<IP address>
Ê
The
Firmware Update
page opens:
Figure 47: Firmware recovery via HTTP (as depicted in Internet Explorer)
4. Select firmware file for download.
Ø
Click
Browse…
button, to open a dialog window for selecting the
firmware file you want to download.
Ø
Navigate to the directory in which the firmware file is stored, select the
file, then click
Open
.
Note:
The name of the firmware file for the EU5C-SWD-SERCOS
gateway is E030J0U0.nxf
Ê
Path and name of the selected file are displayed in the field next to the
Browse…
button.
SmartWire-DT Gateway | EU5C-SWD-SERCOS
DOC160805UM01EN | Revision 1 | English | 2017-02 | Released | Public
© Hilscher 2017